On energy discharge profile in spark test apparatus

Even if the prospects for using hydrogen as an energy vector fluctuate, current trends will increase the incidence of hazardous areas, especially those due to hydrogen. In the context of increased intelligence implemented to control and improve the efficiency of technological systems, low-current installations are of greater importance. Certification is a process that confirms the implementation of explosion protection in equipment and systems through a legal means. An important step in this process, in addition to evaluation, is the testing of the equipment. For confirmation of the type of intrinsic safety protection by test, reference curves from the specific standard or the spark test apparatus (STA) are used. The method, which is based on the use of the STA, is influenced by a stochastic process. This raises problems with the consistency of the results. This fact was highlighted in a proficiency testing session, which at the end showed a dispersion of relative values in the range of -100%400%. With the present work, the authors aim to statistically analyze the discharges in terms of energy, identify and characterize an emerging dispersion profile. Preliminary tests have revealed the existence of additional noise that may affect the measurements; therefore, part of the present effort is to identify and filter out this interference. In the first part of the paper, the STA and its relevant parameters are presented. Also on this occasion, the test stand used to obtain the energy discharged into the device in its calibration process is presented. The next part was devoted to the presentation of the results and discussions. An important conclusion of the work is that, for the test conditions used, the energy discharged in the STA exhibits nonuniform dispersion of energy values and is characterized by several attractors.

Authors

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2025-12-18
DOI
https://doi.org/10.1051/matecconf/202541800021/pdf
Primary Topic
Industrial and Mining Safety
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

On energy discharge profile in spark test apparatus

Marius Darie, Tiberiu Csaszar, Clementina Moldovan
Springer Link (Chiba Institute of Technology)
Industrial and Mining Safety
article

On energy discharge profile in spark test apparatus

Marius Darie, Tiberiu Csaszar, Clementina Moldovan
article en

Abstract

Even if the prospects for using hydrogen as an energy vector fluctuate, current trends will increase the incidence of hazardous areas, especially those due to hydrogen. In the context of increased intelligence implemented to control and improve the efficiency of technological systems, low-current installations are of greater importance. Certification is a process that confirms the implementation of explosion protection in equipment and systems through a legal means. An important step in this process, in addition to evaluation, is the testing of the equipment. For confirmation of the type of intrinsic safety protection by test, reference curves from the specific standard or the spark test apparatus (STA) are used. The method, which is based on the use of the STA, is influenced by a stochastic process. This raises problems with the consistency of the results. This fact was highlighted in a proficiency testing session, which at the end showed a dispersion of relative values in the range of -100%400%. With the present work, the authors aim to statistically analyze the discharges in terms of energy, identify and characterize an emerging dispersion profile. Preliminary tests have revealed the existence of additional noise that may affect the measurements; therefore, part of the present effort is to identify and filter out this interference. In the first part of the paper, the STA and its relevant parameters are presented. Also on this occasion, the test stand used to obtain the energy discharged into the device in its calibration process is presented. The next part was devoted to the presentation of the results and discussions. An important conclusion of the work is that, for the test conditions used, the energy discharged in the STA exhibits nonuniform dispersion of energy values and is characterized by several attractors.

Springer Link (Chiba Institute of Technology)
Affordable and clean energy
Openalex Percentile: Top 37%
Industrial and Mining Safety
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.