Knowledge Graph and LSTM-Based Risk Identification and Fault Management Model for Smart Substations

In the active landscape of 6G wi-fi systems, combining knowledge graph technology and advanced data analysis strategies presents a transformative approach to monitoring and managing relay protection status in intelligent substations. This paper implements a risk identification framework for relay protection equipment operation in smart substations. Based on this, the paper proposes an innovative Knowledge Graph (KG) -based risk identification model that effectively combines the remote tracking abilities of KG with advanced predictive and analytical ability to ensure efficient, accurate, and reliable control over substation equipment. Our model facilitates real-time data collection and exchange by combining interconnected devices with sensors, actuators, and network connectivity, improving substations' operational performance and risk management. The LSTM component was also introduced, which is well-suited for analysing the time series data and also applied to monitor operational patterns, detect anomalies, and predict the future risk of failures. Simultaneously, the KG-based system is effectively used for local fault cases to identify risky equipment and become aware of fault paths within the substation's network. This approach effectively minimises human intervention by automating the monitoring process and significantly reducing the dependence on traditional, costly solutions. The proposed design consists of three key modules - KG-LSTM-FD for fault detection, KG-LSTM-RI for risk identification, and KG-LSTM-FL for fault location estimation. Our model proved exceptional sensitivity and reliability, achieving a 99.98% successful rate throughout diverse fault scenarios with location estimation errors within 1%. The KG-LSTM-based risk identification model, examined through a prototype system, marks a tremendous advancement in combining the physical world with computer-based systems, providing a costeffective, highly efficient, and scalable solution for the next generation of smart substations.

Authors

Institutions

Publication Details

Journal
Journal of Circuits Systems and Computers
Published
2025-12-23
DOI
https://doi.org/10.1142/s0218126626500908
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Knowledge Graph and LSTM-Based Risk Identification and Fault Management Model for Smart Substations

Deliang Tian, Maoran Zheng, Zhaohui Chen, Jie Li
Journal of Circuits Systems and Computers
Power Systems Fault Detection
article

Knowledge Graph and LSTM-Based Risk Identification and Fault Management Model for Smart Substations

Deliang Tian, Maoran Zheng, Zhaohui Chen, Jie Li
article en

Abstract

In the active landscape of 6G wi-fi systems, combining knowledge graph technology and advanced data analysis strategies presents a transformative approach to monitoring and managing relay protection status in intelligent substations. This paper implements a risk identification framework for relay protection equipment operation in smart substations. Based on this, the paper proposes an innovative Knowledge Graph (KG) -based risk identification model that effectively combines the remote tracking abilities of KG with advanced predictive and analytical ability to ensure efficient, accurate, and reliable control over substation equipment. Our model facilitates real-time data collection and exchange by combining interconnected devices with sensors, actuators, and network connectivity, improving substations' operational performance and risk management. The LSTM component was also introduced, which is well-suited for analysing the time series data and also applied to monitor operational patterns, detect anomalies, and predict the future risk of failures. Simultaneously, the KG-based system is effectively used for local fault cases to identify risky equipment and become aware of fault paths within the substation's network. This approach effectively minimises human intervention by automating the monitoring process and significantly reducing the dependence on traditional, costly solutions. The proposed design consists of three key modules - KG-LSTM-FD for fault detection, KG-LSTM-RI for risk identification, and KG-LSTM-FL for fault location estimation. Our model proved exceptional sensitivity and reliability, achieving a 99.98% successful rate throughout diverse fault scenarios with location estimation errors within 1%. The KG-LSTM-based risk identification model, examined through a prototype system, marks a tremendous advancement in combining the physical world with computer-based systems, providing a costeffective, highly efficient, and scalable solution for the next generation of smart substations.

Journal of Circuits Systems and Computers
Twitter (United States) (US)
Openalex Percentile: Top 38%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.