Effect of Lithium-Disilicate Liners on Bond Strength and Fracture Resistance of Bilayered Zirconia Systems: A Systematic Review of In Vitro Evidence

<b>Background</b>/<b>Objectives:</b> Chipping of the veneering part of the crown at the zirconia-porcelain interface remains a major complication of bilayered zirconia systems. This systematic review evaluated whether incorporating a lithium-disilicate (LD) liner or press-on or CAD-on interlayer between zirconia and veneer improves bond strength and fracture performance in vitro. <b>Methods:</b> Following PRISMA 2020, we searched PubMed, Scopus, and Web of Science up to 7 September 2025 for open-access English in vitro studies using LD-based interlayers at zirconia-veneer interfaces and reporting quantitative bond and/or fracture outcomes. Data included extracted materials, processing parameters, and mechanical results; due to heterogeneity, findings were synthesized descriptively and as the ratio-of-means (ROM). <b>Results:</b> Five in vitro studies from Korea, Thailand, and India met the criteria. LD interlayers increased microtensile bond strength from 18.83 to 44.20 MPa and from 19.6 to 47.7 MPa, and shear bond strength from 41.3 to 59.7 MPa, 11.40 ± 1.29 to 18.81 ± 1.76 MPa, and 21.5 to 60.2 MPa. Corresponding ROMs ranged from 1.46 to 2.80 (median 2.35), with thermocycled LD groups maintaining strengths >25 MPa. LD liners also raised crown fracture loads from ~2.18 to ~3.45 kN and characteristic strength from 3.42 to 5.64 kN, while chipping loads in implant crowns increased from ~0.34 to ~0.84 kN and global fracture from ~1.71 to ~1.93 kN. <b>Conclusions:</b> Across diverse zirconia-veneer configurations, LD interlayers consistently enhanced bond metrics and fracture/chipping resistance, supporting their use as a targeted interfacial strategy; however, clinical confirmation is still needed.

Authors

Institutions

Publication Details

Journal
Dentistry Journal
Published
2025-12-22
DOI
https://doi.org/10.3390/dj14010005
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of Lithium-Disilicate Liners on Bond Strength and Fracture Resistance of Bilayered Zirconia Systems: A Systematic Review of In Vitro Evidence

Alexandra Cristina Maroiu, Magda Mihaela Luca, Anca Jivanescu
Dentistry Journal
Dental materials and restorations
article

Effect of Lithium-Disilicate Liners on Bond Strength and Fracture Resistance of Bilayered Zirconia Systems: A Systematic Review of In Vitro Evidence

Alexandra Cristina Maroiu, Magda Mihaela Luca, Anca Jivanescu
article en

Abstract

<b>Background</b>/<b>Objectives:</b> Chipping of the veneering part of the crown at the zirconia-porcelain interface remains a major complication of bilayered zirconia systems. This systematic review evaluated whether incorporating a lithium-disilicate (LD) liner or press-on or CAD-on interlayer between zirconia and veneer improves bond strength and fracture performance in vitro. <b>Methods:</b> Following PRISMA 2020, we searched PubMed, Scopus, and Web of Science up to 7 September 2025 for open-access English in vitro studies using LD-based interlayers at zirconia-veneer interfaces and reporting quantitative bond and/or fracture outcomes. Data included extracted materials, processing parameters, and mechanical results; due to heterogeneity, findings were synthesized descriptively and as the ratio-of-means (ROM). <b>Results:</b> Five in vitro studies from Korea, Thailand, and India met the criteria. LD interlayers increased microtensile bond strength from 18.83 to 44.20 MPa and from 19.6 to 47.7 MPa, and shear bond strength from 41.3 to 59.7 MPa, 11.40 ± 1.29 to 18.81 ± 1.76 MPa, and 21.5 to 60.2 MPa. Corresponding ROMs ranged from 1.46 to 2.80 (median 2.35), with thermocycled LD groups maintaining strengths >25 MPa. LD liners also raised crown fracture loads from ~2.18 to ~3.45 kN and characteristic strength from 3.42 to 5.64 kN, while chipping loads in implant crowns increased from ~0.34 to ~0.84 kN and global fracture from ~1.71 to ~1.93 kN. <b>Conclusions:</b> Across diverse zirconia-veneer configurations, LD interlayers consistently enhanced bond metrics and fracture/chipping resistance, supporting their use as a targeted interfacial strategy; however, clinical confirmation is still needed.

Dentistry JournalVol. 14(1)
Victor Babeș University of Medicine and Pharmacy Timișoara (RO)
Openalex Percentile: Top 34%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.