Custom Sleeve Parameters in Static Guided Endodontic Access: Influence on Deviation Control in Pulp Canal Obliteration
The SGEA technique provided higher accuracy than freehand access in controlling drilling deviation. Among the tested parameters, the custom 3D-printed zirconia sleeve with a 7 mm height yielded the best precision, supporting its potential use in minimizing iatrogenic risk during endodontic access of obliterated canals. This in vitro study on resin models requires further in vivo validation for clinical application.
Authors
- Satrio Wicaksono (ORCID: https://orcid.org/0000-0002-1340-7630)
- Anna Muryani (ORCID: https://orcid.org/0000-0003-2228-5433)
- Dudi Aripin (ORCID: https://orcid.org/0000-0002-0669-1936)
- Wandi Prasetia
- Zainul Rajion
- Hendra Dian Dharsono
Institutions
- Bandung Institute of Technology (ID)
- International Islamic University Malaysia (MY)
- Padjadjaran University (ID)
Publication Details
- Journal
- Clinical Cosmetic and Investigational Dentistry
- Published
- 2025-12-01
- DOI
- https://doi.org/10.2147/ccide.s563295
- Primary Topic
- Endodontics and Root Canal Treatments
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- International Islamic University Malaysia
- Institut Teknologi Bandung
- Universitas Padjadjaran
- Direktorat Riset dan Pengabdian Masyarakat