Bone-mimicking TPMS gyroid design for osteoporotic fracture fixation: analysis of structural efficiency with simulation study on 316L stainless steel

Abstract Fracture fixation devices for load-bearing bones are typically made from stainless steel, titanium, or cobalt-chromium alloys, but their high stiffness can cause stress shielding with detrimental effect on bone density, reducing implant anchorage, leading to implant loosening, particularly in osteoporotic bones. Low-elastic materials reduce stress shielding, but issues with implant anchorage in fixation of brittle bone cause persistent implant failures. Effective management of porous designs that promote bone ingrowth while maintaining structural efficiency is crucial in these cases. This study addresses the issue by proposing gyroid-based lattice designs that mimic cortical bone porosity (5–15%) for fracture fixation plates, aiming to reduce stress shielding and enhance bone ingrowth for improved anchorage. A three-stage Implicit Finite Element Analysis (FEA) was performed using Ansys. Static four-point bending simulations confirmed the design's suitability for 316L stainless steel in femur, tibia, and humerus fixation in accordance with United States Food and Drug Administration (US-FDA) criteria. Tensile simulations showed a reduction in Young’s modulus from 193 to 178 GPa, indicating an 8% reduction in elasticity. This shift moves closer to the elasticity of bone, representing progress in minimizing stress shielding effect while balancing strength. Biomechanical simulation with plate and bone interaction also demonstrated six-time increased stress flow to the bone with porous gyroid structured implant. In comparison, simple cubic lattice designs failed to meet US-FDA criteria, while the gyroid designs exhibited 25% higher mechanical properties. The gyroid design shows promise in improving bone stability, reducing stress shielding, and meeting US-FDA performance criteria in load-bearing fractures. Graphical abstract

Authors

Institutions

Publication Details

Journal
International Journal on Interactive Design and Manufacturing (IJIDeM)
Published
2025-12-26
DOI
https://doi.org/10.1007/s12008-025-02476-3
Primary Topic
Cellular and Composite Structures
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Bone-mimicking TPMS gyroid design for osteoporotic fracture fixation: analysis of structural efficiency with simulation study on 316L stainless steel

Ashfaq Mohammad, Mohammad Alkhreisat, Neil Shearer, Fadi Kahwash et al.
International Journal on Interactive Design and Manufacturing (IJIDeM)
Cellular and Composite Structures
article

Bone-mimicking TPMS gyroid design for osteoporotic fracture fixation: analysis of structural efficiency with simulation study on 316L stainless steel

Ashfaq Mohammad, Mohammad Alkhreisat, Neil Shearer, Fadi Kahwash, Khamis Essa, Islam Shyha, M. G. Shaikh, Kedarnath Rane
article en

Abstract

Abstract Fracture fixation devices for load-bearing bones are typically made from stainless steel, titanium, or cobalt-chromium alloys, but their high stiffness can cause stress shielding with detrimental effect on bone density, reducing implant anchorage, leading to implant loosening, particularly in osteoporotic bones. Low-elastic materials reduce stress shielding, but issues with implant anchorage in fixation of brittle bone cause persistent implant failures. Effective management of porous designs that promote bone ingrowth while maintaining structural efficiency is crucial in these cases. This study addresses the issue by proposing gyroid-based lattice designs that mimic cortical bone porosity (5–15%) for fracture fixation plates, aiming to reduce stress shielding and enhance bone ingrowth for improved anchorage. A three-stage Implicit Finite Element Analysis (FEA) was performed using Ansys. Static four-point bending simulations confirmed the design's suitability for 316L stainless steel in femur, tibia, and humerus fixation in accordance with United States Food and Drug Administration (US-FDA) criteria. Tensile simulations showed a reduction in Young’s modulus from 193 to 178 GPa, indicating an 8% reduction in elasticity. This shift moves closer to the elasticity of bone, representing progress in minimizing stress shielding effect while balancing strength. Biomechanical simulation with plate and bone interaction also demonstrated six-time increased stress flow to the bone with porous gyroid structured implant. In comparison, simple cubic lattice designs failed to meet US-FDA criteria, while the gyroid designs exhibited 25% higher mechanical properties. The gyroid design shows promise in improving bone stability, reducing stress shielding, and meeting US-FDA performance criteria in load-bearing fractures. Graphical abstract

International Journal on Interactive Design and Manufacturing (IJIDeM)Vol. 20(3)
University of Strathclyde (GB), Edinburgh Napier University (GB), Al-Balqa Applied University (JO), University of Birmingham (GB)
Openalex Percentile: Top 45%
Cellular and Composite Structures
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.