Design and Experimental Validation of a Round Inductosyn-Based Angular Measurement System
This paper presents the design, implementation, and experimental validation of a high-precision angular measurement system based on a round inductosyn. Dedicated hardware circuits, including excitation, signal conditioning, and resolver-to-digital conversion modules, together with software algorithms for coarse-fine data fusion and linear interpolation-based error compensation, are developed to achieve accurate and stable angular measurement. Experimental results obtained from repeated measurements over a full rotation demonstrate reliable system operation and effective suppression of nonlinear errors. After compensation, the residual angular error is limited to within ±3″, while measurement consistency across repeated experiments is significantly improved. The output angle exhibits good continuity and stability, confirming the feasibility and effectiveness of the proposed system for high-precision servo control and aerospace attitude measurement applications.
Authors
- Jian Wang (ORCID: https://orcid.org/0000-0003-4670-7741)
- Jianyuan Wang (ORCID: https://orcid.org/0000-0003-4986-1031)
- Jinbao Chen
- Chukang Zhong
- Yuankui Shao
Institutions
- Nanjing University of Aeronautics and Astronautics (CN)
Publication Details
- Journal
- Micromachines
- Published
- 2025-12-20
- DOI
- https://doi.org/10.3390/mi17010005
- Primary Topic
- Sensor Technology and Measurement Systems
- Type
- article
- Field-Weighted Citation Impact
- 0.00