Changes of microbial communities in loose sediments with accumulation time in chlorinated drinking water distribution systems

'Yellow water' issues frequently occur in drinking water supply systems on university campuses, primarily caused by the resuspension of loose sediments within pipelines, which may pose high potential microbiological risks. In order to investigate the accumulation of sediments accompanying microbiological risks in municipal pipelines, 'water + sediment' samples were collected periodically over two semesters in a university campus exhibiting divergent temperature patterns. Results indicated that sediment quantity increased rapidly within a short period; however, microbial biomass did not increase significantly. During the second semester with rising temperatures, the abundance of potential pathogens like <i>Legionella</i> spp. and <i>Mycobacterium</i> spp. increased markedly. Microbial community structure underwent an obvious succession over time in both semesters. This study found that short-term sediment accumulation in university campus drinking water supply systems did not pose immediate microbiological risks under the studied conditions. Pipeline pre-flushing before the start of each semester was recommended to mitigate microbiological risks.

Authors

Institutions

Publication Details

Journal
Biofouling
Published
2025-12-22
DOI
https://doi.org/10.1080/08927014.2025.2603454
Primary Topic
Water Treatment and Disinfection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Changes of microbial communities in loose sediments with accumulation time in chlorinated drinking water distribution systems

Xiang Li, Guofang Cai, Minjia Zheng, Xiaomei Li et al.
Biofouling
Water Treatment and Disinfection
article

Changes of microbial communities in loose sediments with accumulation time in chlorinated drinking water distribution systems

Xiang Li, Guofang Cai, Minjia Zheng, Xiaomei Li, Dong Hu, Kang An, Zhan Sun, Hui Yang, Yifei Jiang
article en

Abstract

'Yellow water' issues frequently occur in drinking water supply systems on university campuses, primarily caused by the resuspension of loose sediments within pipelines, which may pose high potential microbiological risks. In order to investigate the accumulation of sediments accompanying microbiological risks in municipal pipelines, 'water + sediment' samples were collected periodically over two semesters in a university campus exhibiting divergent temperature patterns. Results indicated that sediment quantity increased rapidly within a short period; however, microbial biomass did not increase significantly. During the second semester with rising temperatures, the abundance of potential pathogens like <i>Legionella</i> spp. and <i>Mycobacterium</i> spp. increased markedly. Microbial community structure underwent an obvious succession over time in both semesters. This study found that short-term sediment accumulation in university campus drinking water supply systems did not pose immediate microbiological risks under the studied conditions. Pipeline pre-flushing before the start of each semester was recommended to mitigate microbiological risks.

BiofoulingVol. 42(1)
Academy of Medical Sciences (GB), Xiamen University (CN), Xian Center for Disease Control and Prevention (CN), Taiwan Centers for Disease Control (TW), Shandong First Medical University (CN), Shandong Center for Disease Control and Prevention (CN)
Clean water and sanitation
Openalex Percentile: Top 34%
Water Treatment and Disinfection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.