A Compact Polarimetric CTLR Mode Calibration Method Immune to Faraday Rotation Using Two Dihedral Reflectors

This paper proposes a compact polarimetric CTLR mode calibration method using only two dihedral reflectors. The method leverages the property that the dihedral scattering matrix is unaffected by double-pass Faraday rotation, effectively eliminating the interference of Faraday rotation on distortion parameter estimation. By selecting any two from four dihedral reflectors rotated at 0°, 22.5°, 45°, and 67.5°, the system distortion parameters can be estimated. To resolve the two-fold solution ambiguity inherent in the estimation process, two ambiguity elimination methods are proposed: Method I selects the solution with equivalent crosstalk magnitude less than 0 dB based on the prior knowledge that the transmit antenna is dominated by right-hand circular polarization; Method II employs cross-validation using different dihedral combinations with distinct product constants, applicable when the prior knowledge does not hold. Through simulation analysis, the algorithm’s sensitivity to receive crosstalk levels, signal-to-noise ratio, and polarization orientation angle shift is evaluated. The results demonstrate that to maintain residual receive imbalance amplitude within ±1 dB, phase within ±10°, and residual equivalent crosstalk below −30 dB, the system received crosstalk must be lower than −25 dB, the signal-to-noise ratio must exceed 35 dB, and polarization orientation angle shift should be controlled within ±1°. The effectiveness of the proposed algorithm is validated using fully polarimetric calibrated GaoFen-3 satellite data, achieving root mean square errors of 0.10 dB, 1.13°, and 0.42 dB for amplitude imbalance, phase imbalance, and equivalent crosstalk amplitude, respectively. Comparative analysis demonstrates that the proposed method achieves significantly higher calibration accuracy than existing approaches, with substantial improvements in parameter estimation precision.

Authors

Institutions

Publication Details

Journal
Remote Sensing
Published
2025-12-23
DOI
https://doi.org/10.3390/rs18010037
Primary Topic
Soil Moisture and Remote Sensing
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Compact Polarimetric CTLR Mode Calibration Method Immune to Faraday Rotation Using Two Dihedral Reflectors

Xiuqing Liu, Jili Sun, Siqi Liu
Remote Sensing
Soil Moisture and Remote Sensing
article

A Compact Polarimetric CTLR Mode Calibration Method Immune to Faraday Rotation Using Two Dihedral Reflectors

Xiuqing Liu, Jili Sun, Siqi Liu
article en

Abstract

This paper proposes a compact polarimetric CTLR mode calibration method using only two dihedral reflectors. The method leverages the property that the dihedral scattering matrix is unaffected by double-pass Faraday rotation, effectively eliminating the interference of Faraday rotation on distortion parameter estimation. By selecting any two from four dihedral reflectors rotated at 0°, 22.5°, 45°, and 67.5°, the system distortion parameters can be estimated. To resolve the two-fold solution ambiguity inherent in the estimation process, two ambiguity elimination methods are proposed: Method I selects the solution with equivalent crosstalk magnitude less than 0 dB based on the prior knowledge that the transmit antenna is dominated by right-hand circular polarization; Method II employs cross-validation using different dihedral combinations with distinct product constants, applicable when the prior knowledge does not hold. Through simulation analysis, the algorithm’s sensitivity to receive crosstalk levels, signal-to-noise ratio, and polarization orientation angle shift is evaluated. The results demonstrate that to maintain residual receive imbalance amplitude within ±1 dB, phase within ±10°, and residual equivalent crosstalk below −30 dB, the system received crosstalk must be lower than −25 dB, the signal-to-noise ratio must exceed 35 dB, and polarization orientation angle shift should be controlled within ±1°. The effectiveness of the proposed algorithm is validated using fully polarimetric calibrated GaoFen-3 satellite data, achieving root mean square errors of 0.10 dB, 1.13°, and 0.42 dB for amplitude imbalance, phase imbalance, and equivalent crosstalk amplitude, respectively. Comparative analysis demonstrates that the proposed method achieves significantly higher calibration accuracy than existing approaches, with substantial improvements in parameter estimation precision.

Remote SensingVol. 18(1)
Chinese Academy of Sciences (CN), Aerospace Information Research Institute (CN), University of Chinese Academy of Sciences (CN)
Affordable and clean energy
Openalex Percentile: Top 43%
Soil Moisture and Remote Sensing
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.