Rationale Laser ablation mass spectrometry provides fast and direct chemical information of solids with high spatial resolution without the need for complex sample preparation. It has been shown that reducing the laser pulse length below picoseconds improves the quantification of chemical composition measurements of solids. This study compares the impact on chemical quantification of applying femtosecond laser ablation from IR to UV wavelengths to a steel alloy sample from NIST.Methods A compact laser ablation ionisation mass spectrometer (LIMS), coupled to a fs laser ablation ion source with a fundamental laser wavelength of 775 nm, is used for the presented mass spectrometric results. The fundamental wavelength is frequency doubled or tripled to 387 and 258 nm, respectively. An extensive mass spectrometric campaign, comprising various laser pulse energies, was conducted using the NIST iron alloy standard reference material 664. The recorded element composition was compared with the NIST certified values.Results Chemical composition analysis demonstrated the presence of significant chemical inhomogeneity of the NIST reference samples at spatial scales of about 10 μm, particularly in Ti and S. Large deviations identified were avoided for the presented study. A score was calculated for each of the accumulated spectra, indicating how close the measured composition reflected the certified values. The results show only minor differences between the wavelengths applied for sufficiently high irradiances.Conclusions These studies conducted on steel alloy NIST SRM 664 demonstrate that the impact of laser wavelength on the quantification becomes only noticeable for low irradiances. At sufficiently high laser irradiances at around 3.1 TW/cm2 and beyond, comparable calibration coefficients can be observed.

Authors

Institutions

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2025-12-22
DOI
https://doi.org/10.48620/93307
Primary Topic
Laser-induced spectroscopy and plasma
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Wavelength Dependence of fs Laser Ablation Ionisation Mass Spectrometry: a Dedicated Study on NIST SRM 664.

Peter Wurz, Andreas Riedo, Valentine Grimaudo, Marek Tulej
Open Access CRIS of the University of Bern
Laser-induced spectroscopy and plasma
article

Wavelength Dependence of fs Laser Ablation Ionisation Mass Spectrometry: a Dedicated Study on NIST SRM 664.

Peter Wurz, Andreas Riedo, Valentine Grimaudo, Marek Tulej
article en

Abstract

Rationale Laser ablation mass spectrometry provides fast and direct chemical information of solids with high spatial resolution without the need for complex sample preparation. It has been shown that reducing the laser pulse length below picoseconds improves the quantification of chemical composition measurements of solids. This study compares the impact on chemical quantification of applying femtosecond laser ablation from IR to UV wavelengths to a steel alloy sample from NIST.Methods A compact laser ablation ionisation mass spectrometer (LIMS), coupled to a fs laser ablation ion source with a fundamental laser wavelength of 775 nm, is used for the presented mass spectrometric results. The fundamental wavelength is frequency doubled or tripled to 387 and 258 nm, respectively. An extensive mass spectrometric campaign, comprising various laser pulse energies, was conducted using the NIST iron alloy standard reference material 664. The recorded element composition was compared with the NIST certified values.Results Chemical composition analysis demonstrated the presence of significant chemical inhomogeneity of the NIST reference samples at spatial scales of about 10 μm, particularly in Ti and S. Large deviations identified were avoided for the presented study. A score was calculated for each of the accumulated spectra, indicating how close the measured composition reflected the certified values. The results show only minor differences between the wavelengths applied for sufficiently high irradiances.Conclusions These studies conducted on steel alloy NIST SRM 664 demonstrate that the impact of laser wavelength on the quantification becomes only noticeable for low irradiances. At sufficiently high laser irradiances at around 3.1 TW/cm2 and beyond, comparable calibration coefficients can be observed.

Open Access CRIS of the University of Bern
Planetary Science Institute (US), Lunar and Planetary Institute (US)
Openalex Percentile: Top 43%
Laser-induced spectroscopy and plasma
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.