HighRes‐Net: Physics‐Informed Deep Learning Framework for High‐Resolution Fat–Water Imaging

ABSTRACT Fat–water separation in 3T scanners is challenging due to the rapid signal loss due to faster dephasing, pronounced field inhomogeneities, and short echo‐spacing requirements that limit high‐resolution fat–water imaging. This study evaluates a novel deep learning (DL) framework, HighRes‐Net, for the challenging task of fat–water separation in high‐resolution single‐shot multi‐echo MRIs acquired at 3T. The proposed HighRes‐Net has DL networks and a biophysical equation–based loss function that are combined specially for handling fat–water separation in low signal‐to‐noise ratio (SNR) high‐resolution multi‐echo MRIs. A novel DL architecture for handling phase errors and the regularized and accurate estimation of field inhomogeneity maps is also introduced. The HighRes‐Net utilizes the ad hoc reconstruction technique using the biophysical equation–based loss that accounts for phase errors. Novel echo‐wise weighting is introduced in this biophysical equation–based loss to account for signal loss in farther echoes. Unlike conventional DL methods, HighRes‐Net employs a subject‐specific ad hoc reconstruction strategy, requiring no large training dataset and avoiding generalizability issues. Efficacy of the HighRes‐Net is evaluated using three types of test datasets, including a high‐resolution dataset acquired at 3T. The liver proton density fat fraction% (PDFF%) values obtained from the test datasets are compared with those obtained from a mDixon Quant sequence run in low‐resolution settings with parameters optimized for accurate fat quantification. The quantitative results demonstrated that the PDFF% values from the HighRes‐Net agreed with those from the mDixon Quant sequence, even in the high‐resolution dataset. The qualitative results demonstrated that the HighRes‐Net produced fat–water maps without swap artifacts. HighRes‐Net enables reliable fat–water separation in high‐resolution 3T multi‐echo MRI, addressing the SNR limitations that hinder conventional techniques and expanding the potential of clinical fat quantification.

Authors

Institutions

Publication Details

Journal
NMR in Biomedicine
Published
2025-12-22
DOI
https://doi.org/10.1002/nbm.70216
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

HighRes‐Net: Physics‐Informed Deep Learning Framework for High‐Resolution Fat–Water Imaging

Amit Mehndiratta, Devasenathipathy Kandasamy, M Ganeshkumar, Raju Sharma et al.
NMR in Biomedicine
Advanced MRI Techniques and Applications
article

HighRes‐Net: Physics‐Informed Deep Learning Framework for High‐Resolution Fat–Water Imaging

Amit Mehndiratta, Devasenathipathy Kandasamy, M Ganeshkumar, Raju Sharma, Rajnandini Dasgupta, Somil Anshal, * Shalimar
article en

Abstract

ABSTRACT Fat–water separation in 3T scanners is challenging due to the rapid signal loss due to faster dephasing, pronounced field inhomogeneities, and short echo‐spacing requirements that limit high‐resolution fat–water imaging. This study evaluates a novel deep learning (DL) framework, HighRes‐Net, for the challenging task of fat–water separation in high‐resolution single‐shot multi‐echo MRIs acquired at 3T. The proposed HighRes‐Net has DL networks and a biophysical equation–based loss function that are combined specially for handling fat–water separation in low signal‐to‐noise ratio (SNR) high‐resolution multi‐echo MRIs. A novel DL architecture for handling phase errors and the regularized and accurate estimation of field inhomogeneity maps is also introduced. The HighRes‐Net utilizes the ad hoc reconstruction technique using the biophysical equation–based loss that accounts for phase errors. Novel echo‐wise weighting is introduced in this biophysical equation–based loss to account for signal loss in farther echoes. Unlike conventional DL methods, HighRes‐Net employs a subject‐specific ad hoc reconstruction strategy, requiring no large training dataset and avoiding generalizability issues. Efficacy of the HighRes‐Net is evaluated using three types of test datasets, including a high‐resolution dataset acquired at 3T. The liver proton density fat fraction% (PDFF%) values obtained from the test datasets are compared with those obtained from a mDixon Quant sequence run in low‐resolution settings with parameters optimized for accurate fat quantification. The quantitative results demonstrated that the PDFF% values from the HighRes‐Net agreed with those from the mDixon Quant sequence, even in the high‐resolution dataset. The qualitative results demonstrated that the HighRes‐Net produced fat–water maps without swap artifacts. HighRes‐Net enables reliable fat–water separation in high‐resolution 3T multi‐echo MRI, addressing the SNR limitations that hinder conventional techniques and expanding the potential of clinical fat quantification.

NMR in BiomedicineVol. 39(2)
UNSW Sydney (AU), All India Institute of Medical Sciences (IN), Indian Institute of Technology Delhi (IN)
Clean water and sanitation
Openalex Percentile: Top 31%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.