The opportunity of using an integrated system for testing equipment with type of protection 'p' – pressurized enclosure

In the field of equipment intended for use in potentially explosive atmospheres, rigorous testing is essential to ensure operational safety. For large-scale equipment, explosion protection by pressurization represents a feasible solution. Testing of explosion-protected equipment using pressurization involves applying a sequence of tests designed to ensure the integrity of the enclosure and to analyze the dynamics of dilution processes. Although standard testing sessions do not present significant technical challenges, the large number of monitored parameters and the complexity of required actions necessitate the use of an integrated monitoring and control system for the testing parameters. The first part of the paper presents the testing procedure sequence, including the relevant performance requirements. The second part identifies the parameters that must be monitored and the actions that need to be triggered during the testing processes. The third part proposes a block structure for the integrated monitoring system of pressurization parameters during testing. The paper concludes that using an integrated system for pressurization testing offers multiple technical and operational advantages.

Authors

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2025-12-18
DOI
https://doi.org/10.1051/matecconf/202541800024/pdf
Primary Topic
Industrial and Mining Safety
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The opportunity of using an integrated system for testing equipment with type of protection 'p' – pressurized enclosure

Gabriela Pupăzan, Cosmin Colda, Tiberiu Csaszar, Dănuț Grecea
Springer Link (Chiba Institute of Technology)
Industrial and Mining Safety
article

The opportunity of using an integrated system for testing equipment with type of protection 'p' – pressurized enclosure

Gabriela Pupăzan, Cosmin Colda, Tiberiu Csaszar, Dănuț Grecea
article en

Abstract

In the field of equipment intended for use in potentially explosive atmospheres, rigorous testing is essential to ensure operational safety. For large-scale equipment, explosion protection by pressurization represents a feasible solution. Testing of explosion-protected equipment using pressurization involves applying a sequence of tests designed to ensure the integrity of the enclosure and to analyze the dynamics of dilution processes. Although standard testing sessions do not present significant technical challenges, the large number of monitored parameters and the complexity of required actions necessitate the use of an integrated monitoring and control system for the testing parameters. The first part of the paper presents the testing procedure sequence, including the relevant performance requirements. The second part identifies the parameters that must be monitored and the actions that need to be triggered during the testing processes. The third part proposes a block structure for the integrated monitoring system of pressurization parameters during testing. The paper concludes that using an integrated system for pressurization testing offers multiple technical and operational advantages.

Springer Link (Chiba Institute of Technology)
Openalex Percentile: Top 37%
Industrial and Mining Safety
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.