Adjunct Automated Breast Ultrasound in Mammographic Screening: A Systematic Review and Meta-Analysis

Mammographic sensitivity is reduced in women with dense breasts, leading to missed cancers and a higher burden of interval cancers. Automated breast ultrasound (ABUS) and ultrasound tomography (UST) have been introduced as supplemental breast imaging modalities, but primary studies are heterogeneous, and previous reviews have not focused on screening settings or on head-to-head comparisons with handheld ultrasound (HHUS). We systematically searched PubMed, Embase, Web of Science and the Cochrane Library for studies from 1 January 2000 to 31 May 2025 evaluating ABUS or UST as adjuncts to mammographic screening. Two reviewers independently selected studies and assessed risk of bias. When at least two clinically comparable studies were available, we pooled sensitivity and specificity using random-effects bivariate meta-analysis. Eighteen studies (just over 20,000 screening or recall episodes) met the inclusion criteria; 16 evaluated ABUS/ABVS and 2 UST. Adding ABUS to mammography increased sensitivity by 6-35 percentage points and improved cancer detection by 2.4-4.3 per 1000 women with dense breasts, with higher recall rates and modest reductions in specificity. When ABUS was compared directly with HHUS, pooled sensitivity was 0.90 and specificity 0.89, with HHUS showing slightly lower sensitivity and slightly higher specificity. Only two studies had an overall low risk of bias, and heterogeneity (particularly for specificity) was substantial. ABUS is a practical and scalable adjunct to mammography that increases cancer detection in women with dense breasts, with an expected trade-off of higher recall and modest specificity loss. Its comparative diagnostic accuracy appears broadly non-inferior to HHUS. However, the predominance of high-risk-of-bias studies and between-study heterogeneity means that high-quality population-based trials and standardised reporting are still required before widespread implementation in organised screening programmes.

Authors

Institutions

Publication Details

Journal
Journal of Imaging
Published
2025-12-22
DOI
https://doi.org/10.3390/jimaging12010003
Primary Topic
Digital Radiography and Breast Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Adjunct Automated Breast Ultrasound in Mammographic Screening: A Systematic Review and Meta-Analysis

Ghufran Jassim, Suchita Dsilva, Fahad AlZayani
Journal of Imaging
Digital Radiography and Breast Imaging
article

Adjunct Automated Breast Ultrasound in Mammographic Screening: A Systematic Review and Meta-Analysis

Ghufran Jassim, Suchita Dsilva, Fahad AlZayani
article en

Abstract

Mammographic sensitivity is reduced in women with dense breasts, leading to missed cancers and a higher burden of interval cancers. Automated breast ultrasound (ABUS) and ultrasound tomography (UST) have been introduced as supplemental breast imaging modalities, but primary studies are heterogeneous, and previous reviews have not focused on screening settings or on head-to-head comparisons with handheld ultrasound (HHUS). We systematically searched PubMed, Embase, Web of Science and the Cochrane Library for studies from 1 January 2000 to 31 May 2025 evaluating ABUS or UST as adjuncts to mammographic screening. Two reviewers independently selected studies and assessed risk of bias. When at least two clinically comparable studies were available, we pooled sensitivity and specificity using random-effects bivariate meta-analysis. Eighteen studies (just over 20,000 screening or recall episodes) met the inclusion criteria; 16 evaluated ABUS/ABVS and 2 UST. Adding ABUS to mammography increased sensitivity by 6-35 percentage points and improved cancer detection by 2.4-4.3 per 1000 women with dense breasts, with higher recall rates and modest reductions in specificity. When ABUS was compared directly with HHUS, pooled sensitivity was 0.90 and specificity 0.89, with HHUS showing slightly lower sensitivity and slightly higher specificity. Only two studies had an overall low risk of bias, and heterogeneity (particularly for specificity) was substantial. ABUS is a practical and scalable adjunct to mammography that increases cancer detection in women with dense breasts, with an expected trade-off of higher recall and modest specificity loss. Its comparative diagnostic accuracy appears broadly non-inferior to HHUS. However, the predominance of high-risk-of-bias studies and between-study heterogeneity means that high-quality population-based trials and standardised reporting are still required before widespread implementation in organised screening programmes.

Journal of ImagingVol. 12(1)
Royal College of Surgeons in Ireland - Bahrain (BH), Arabian Gulf University (BH)
Openalex Percentile: Top 29%
Digital Radiography and Breast Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.