Biocompatibility Evaluation of Novel Experimental Titanium Alloys for Dental Implants

<b>Background/Objectives</b>: The purpose of this study was to assess the in vitro biocompatibility and corrosion resistance of five titanium alloys that have been recently developed for dental implant applications, whose compositions were designed to align with current approaches in the development of novel biomaterials. Priority was given to limiting the harmfulness associated with specific chemical elements present in common conventional alloys and increasing corrosion resistance to improve the biomaterial-tissue cellular interaction. <b>Methods</b>: For this purpose, five types of titanium alloys with original chemical compositions (Ti1-Ti5) were developed. The electrochemical behavior of the alloys was analyzed by evaluating the corrosion resistance in environments that simulate the oral environment, as well as the cellular behavior, by evaluating the viability, growth, and proliferation of human cells on osteoblasts and gingival fibroblasts. Detailed analysis of the chemical composition by scanning electron microscope (SEM/EDS) methods was used. The corrosion rate of the alloys in artificial saliva was tested using the polarization resistance technique (Tafel). Human osteoblasts (hFOB cell line) and human gingival fibroblasts (hFIB-G cell line) were used to measure biocompatibility in vitro. <b>Results</b>: The Ti5 alloy demonstrated the highest cell viability and the lowest corrosion rate (0.114 μm/year) among all tested compositions, with the Ti3 alloy containing Mo and Zr following closely behind. The Ti2 alloy exhibited reduced biocompatibility because of the inclusion of Ni and Fe in its composition. <b>Conclusions:</b> Taken together, the results of this study provide useful information on the basic characteristics of titanium alloys with original chemical compositions. The titanium alloys were analyzed in comparison with common conventional alloys (Cp-Ti and Ti6Al4V) as well as alloys such as Ti-Zr, Ti-Nb, and Ti-Nb-Zr-Ta, which are considered to be viable alternatives to conventional materials for making dental implants.

Authors

Institutions

Publication Details

Journal
Dentistry Journal
Published
2025-12-22
DOI
https://doi.org/10.3390/dj14010006
Citations
1
Primary Topic
Titanium Alloys Microstructure and Properties
Type
article
Field-Weighted Citation Impact
0.52
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Biocompatibility Evaluation of Novel Experimental Titanium Alloys for Dental Implants

Elisabeta VASILESCU, Florin Miculescu, Diana Maria Vranceanu, Andreea Mihaela Custura et al.
1 citations
Dentistry Journal
Titanium Alloys Microstructure and Properties
0.52
article

Biocompatibility Evaluation of Novel Experimental Titanium Alloys for Dental Implants

Elisabeta VASILESCU, Florin Miculescu, Diana Maria Vranceanu, Andreea Mihaela Custura, Miruna Stan, Marina Imre, Vlad-Gabriel Vasilescu, Lucian Toma Ciocan, Silviu Mirel Pițuru, Cosmin Mihai Cotrut
article en
1 citations

Abstract

<b>Background/Objectives</b>: The purpose of this study was to assess the in vitro biocompatibility and corrosion resistance of five titanium alloys that have been recently developed for dental implant applications, whose compositions were designed to align with current approaches in the development of novel biomaterials. Priority was given to limiting the harmfulness associated with specific chemical elements present in common conventional alloys and increasing corrosion resistance to improve the biomaterial-tissue cellular interaction. <b>Methods</b>: For this purpose, five types of titanium alloys with original chemical compositions (Ti1-Ti5) were developed. The electrochemical behavior of the alloys was analyzed by evaluating the corrosion resistance in environments that simulate the oral environment, as well as the cellular behavior, by evaluating the viability, growth, and proliferation of human cells on osteoblasts and gingival fibroblasts. Detailed analysis of the chemical composition by scanning electron microscope (SEM/EDS) methods was used. The corrosion rate of the alloys in artificial saliva was tested using the polarization resistance technique (Tafel). Human osteoblasts (hFOB cell line) and human gingival fibroblasts (hFIB-G cell line) were used to measure biocompatibility in vitro. <b>Results</b>: The Ti5 alloy demonstrated the highest cell viability and the lowest corrosion rate (0.114 μm/year) among all tested compositions, with the Ti3 alloy containing Mo and Zr following closely behind. The Ti2 alloy exhibited reduced biocompatibility because of the inclusion of Ni and Fe in its composition. <b>Conclusions:</b> Taken together, the results of this study provide useful information on the basic characteristics of titanium alloys with original chemical compositions. The titanium alloys were analyzed in comparison with common conventional alloys (Cp-Ti and Ti6Al4V) as well as alloys such as Ti-Zr, Ti-Nb, and Ti-Nb-Zr-Ta, which are considered to be viable alternatives to conventional materials for making dental implants.

Dentistry JournalVol. 14(1)
University of Bucharest (RO), Carol Davila University of Medicine and Pharmacy (RO), Chamber of Commerce and Industry of Romania (RO), Universitatea Națională de Știință și Tehnologie Politehnica București (RO)
Openalex Percentile: Top 29%
Titanium Alloys Microstructure and Properties
0.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.