Electrical Versus Optical Generation of Leader Signals for Downconversion Leader-Follower Optical Coherence Tomography

The paper refers to advancements in the production of en-face optical coherence tomography (OCT) images from different depths in a sample in real time, using Downconversion Leader-Follower optical coherence tomography method. So far, for a sample placed in an interferometer (Follower), all previous Downconversion Leader-Follower reports employed an interferometer (Leader) to determine the depth where the OCT signal is selected from. In this paper, for the first time, the Leader interferometer is replaced by an arbitrary waveform generator, i.e. optical generation of the reference signal to perform downconversion is replaced by electrical synthesis. In this way, en face images from different depths are presented in real time, without recurring to a second interferometer. Avenues opened by electrical synthesis of signals otherwise provided by interferometers are discussed, with potential to be adopted in signal processing, manipulation and presentation of high resolution images in orthogonal orientations to serve better diagnosis.

Authors

Institutions

Publication Details

Journal
IEEE photonics journal
Published
2025-12-22
DOI
https://doi.org/10.1109/jphot.2025.3646935
Primary Topic
Optical Coherence Tomography Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electrical Versus Optical Generation of Leader Signals for Downconversion Leader-Follower Optical Coherence Tomography

Alejandro Martínez Jiménez, R. Cernat, Adrian Podoleanu
IEEE photonics journal
Optical Coherence Tomography Applications
article

Electrical Versus Optical Generation of Leader Signals for Downconversion Leader-Follower Optical Coherence Tomography

Alejandro Martínez Jiménez, R. Cernat, Adrian Podoleanu
article en

Abstract

The paper refers to advancements in the production of en-face optical coherence tomography (OCT) images from different depths in a sample in real time, using Downconversion Leader-Follower optical coherence tomography method. So far, for a sample placed in an interferometer (Follower), all previous Downconversion Leader-Follower reports employed an interferometer (Leader) to determine the depth where the OCT signal is selected from. In this paper, for the first time, the Leader interferometer is replaced by an arbitrary waveform generator, i.e. optical generation of the reference signal to perform downconversion is replaced by electrical synthesis. In this way, en face images from different depths are presented in real time, without recurring to a second interferometer. Avenues opened by electrical synthesis of signals otherwise provided by interferometers are discussed, with potential to be adopted in signal processing, manipulation and presentation of high resolution images in orthogonal orientations to serve better diagnosis.

IEEE photonics journalVol. 18(1)
University of Kent (GB)
Openalex Percentile: Top 43%
Optical Coherence Tomography Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Electrical Versus Optical Generation of Leader Signals for Downconversion Leader-Follower Optical Coherence Tomography — Alejandro Martínez Jiménez, R. Cernat, et al. · IEEE photonics journal (2025) | TGRS Research Map | TGRS