Quantum correlation imaging via X-ray parametric down-conversion

Quantum imaging leverages correlations between pairs of photons and has the potential to obtain image information beyond what classical sources provide. Extending this approach to the X-ray regime has been limited by low photon-pair generation rates and the lack of suitable detectors. Here, we demonstrate X-ray coincidence imaging using spontaneous parametric down-conversion (SPDC) and a pixelated area detector with time- and energy-resolved capabilities. This configuration enables simultaneous detection of correlated X-ray photon pairs and coincidence-based imaging of test objects, including a biological specimen. The increased coincidence rate and spatially resolved detection establish a basis for future quantum-enhanced and low-dose X-ray imaging.

Authors

Institutions

Publication Details

Journal
Optica
Published
2025-12-22
DOI
https://doi.org/10.1364/optica.574747
Citations
1
Primary Topic
Advanced X-ray Imaging Techniques
Type
article
Field-Weighted Citation Impact
1.88
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantum correlation imaging via X-ray parametric down-conversion

Sanjit Karmakar, Raphael A. Abrahão, K. Gofron, Justin C. Goodrich et al.
1 citations
Optica
Advanced X-ray Imaging Techniques
1.88
article

Quantum correlation imaging via X-ray parametric down-conversion

Sanjit Karmakar, Raphael A. Abrahão, K. Gofron, Justin C. Goodrich, Andrei Fluerasu, Thomas A Caswell, Seán McSweeney, A. Nomerotski, Joseph Hanrahan, Monika Dziubelski, C. DaVià, Lonny Berman, Daniel Allan, Ryan Mahon, Dennis Bollweg
article en
1 citations

Abstract

Quantum imaging leverages correlations between pairs of photons and has the potential to obtain image information beyond what classical sources provide. Extending this approach to the X-ray regime has been limited by low photon-pair generation rates and the lack of suitable detectors. Here, we demonstrate X-ray coincidence imaging using spontaneous parametric down-conversion (SPDC) and a pixelated area detector with time- and energy-resolved capabilities. This configuration enables simultaneous detection of correlated X-ray photon pairs and coincidence-based imaging of test objects, including a biological specimen. The increased coincidence rate and spatially resolved detection establish a basis for future quantum-enhanced and low-dose X-ray imaging.

OpticaVol. 13(1)
Oak Ridge National Laboratory (US), Rochester Institute of Technology (US), Florida International University (US), Brookhaven National Laboratory (US), University of Manchester (GB), Simons Foundation (US), Czech Technical University in Prague (CZ), Stony Brook University (US)
Affordable and clean energy
Openalex Percentile: Top 11%
Advanced X-ray Imaging Techniques
1.88
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Quantum correlation imaging via X-ray parametric down-conversion — Sanjit Karmakar, Raphael A. Abrahão, et al. · Optica (2025) | TGRS Research Map | TGRS