GPU‐based list‐mode TOF PET image reconstruction with complete correction techniques

In phantom studies, QuanTOF achieved uniformity comparable to commercial systems and resolved 2.4 mm hot rods in Derenzo phantoms, with peak-to-valley ratios of 2.61 (3.2 mm rods) and 1.29 (2.4 mm rods). Scatter correction time was reduced to <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:semantics><mml:mrow><mml:mn>0.05</mml:mn> <mml:mo>±</mml:mo> <mml:mn>28.87</mml:mn></mml:mrow> <mml:annotation>$0.05 \pm 28.87$</mml:annotation></mml:semantics> </mml:math> s, two orders of magnitude faster than existing methods. Clinicians rated QuanTOF images significantly higher (average score: 3.90 vs. 2.15 for clinical images) in reader studies. Reconstruction times remained clinically acceptable (e.g., 2.78 s for NEMA phantom scatter correction) CONCLUSIONS: QuanTOF balances accuracy and efficiency through GPU-optimized physics modeling and memory-efficient algorithms. It delivers high-resolution PET images with diagnostic confidence, demonstrating potential for clinical oncology, neurology, and cardiology applications.

Authors

Institutions

Publication Details

Journal
Medical Physics
Published
2025-12-21
DOI
https://doi.org/10.1002/mp.70216
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

GPU‐based list‐mode TOF PET image reconstruction with complete correction techniques

Ziquan Yuan, Yucun Hou, Jianyong Jiang, Haoyu Lu et al.
Medical Physics
Medical Imaging Techniques and Applications
article

GPU‐based list‐mode TOF PET image reconstruction with complete correction techniques

Ziquan Yuan, Yucun Hou, Jianyong Jiang, Haoyu Lu, Chenxi Li, Runze Liao, Fenglin Zhan
article en

Abstract

In phantom studies, QuanTOF achieved uniformity comparable to commercial systems and resolved 2.4 mm hot rods in Derenzo phantoms, with peak-to-valley ratios of 2.61 (3.2 mm rods) and 1.29 (2.4 mm rods). Scatter correction time was reduced to <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:semantics><mml:mrow><mml:mn>0.05</mml:mn> <mml:mo>±</mml:mo> <mml:mn>28.87</mml:mn></mml:mrow> <mml:annotation>$0.05 \pm 28.87$</mml:annotation></mml:semantics> </mml:math> s, two orders of magnitude faster than existing methods. Clinicians rated QuanTOF images significantly higher (average score: 3.90 vs. 2.15 for clinical images) in reader studies. Reconstruction times remained clinically acceptable (e.g., 2.78 s for NEMA phantom scatter correction) CONCLUSIONS: QuanTOF balances accuracy and efficiency through GPU-optimized physics modeling and memory-efficient algorithms. It delivers high-resolution PET images with diagnostic confidence, demonstrating potential for clinical oncology, neurology, and cardiology applications.

Medical PhysicsVol. 53(1)
Jiangnan University (CN), University of Science and Technology of China (CN), The University of Melbourne (AU), Beijing Normal University (CN)
Openalex Percentile: Top 32%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

GPU‐based list‐mode TOF PET image reconstruction with complete correction techniques — Ziquan Yuan, Yucun Hou, et al. · Medical Physics (2025) | TGRS Research Map | TGRS