On-Chip Mid-Infrared Ge-On-Si Platform for Liquid Sensing

Integrated mid-infrared photonics offers a promising route to label-free chemical sensors. In this work, we present a germanium-on-silicon (Ge-on-Si) platform tailored for liquid-phase analysis, with key components optimized for operation at <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$6.9 \mu ~\mathrm{m}$</tex>. We evaluated the sensing performance of this platform for detection of ammonium in aqueous solution resulting in a limit of detection of 108 ppm and a noise floor of <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$10^{-3} \text{AU}$</tex>. The obtained results demonstrate the Ge-on-Si platform's feasibility for continuous, reagent-free monitoring of ionic species in aqueous media. With further refinement and extension of the operating range to longer wavelengths, this approach holds promise for simultaneous, real-time monitoring of different ions including phosphate, for which no reagent-free sensor currently exists.

Authors

Institutions

Publication Details

Published
2025-11-09
DOI
https://doi.org/10.1109/ipc65510.2025.11282164
Primary Topic
Photonic and Optical Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

On-Chip Mid-Infrared Ge-On-Si Platform for Liquid Sensing

Geert Van Steenberge, Tingting Zhai, Alicja Dabrowska, Bernhard Lendl
Photonic and Optical Devices
article

On-Chip Mid-Infrared Ge-On-Si Platform for Liquid Sensing

Geert Van Steenberge, Tingting Zhai, Alicja Dabrowska, Bernhard Lendl
article en

Abstract

Integrated mid-infrared photonics offers a promising route to label-free chemical sensors. In this work, we present a germanium-on-silicon (Ge-on-Si) platform tailored for liquid-phase analysis, with key components optimized for operation at <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$6.9 \mu ~\mathrm{m}$</tex>. We evaluated the sensing performance of this platform for detection of ammonium in aqueous solution resulting in a limit of detection of 108 ppm and a noise floor of <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$10^{-3} \text{AU}$</tex>. The obtained results demonstrate the Ge-on-Si platform's feasibility for continuous, reagent-free monitoring of ionic species in aqueous media. With further refinement and extension of the operating range to longer wavelengths, this approach holds promise for simultaneous, real-time monitoring of different ions including phosphate, for which no reagent-free sensor currently exists.

TU Wien (AT), Ghent University (BE)
Openalex Percentile: Top 43%
Photonic and Optical Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.