Diffusion models vs. DCGANs for class-imbalanced lung cancer CT classification: A comparative study

Effective lung cancer detection from CT scans remains critically challenged by class imbalance where benign and normal cases are underrepresented, leading to biased machine learning models with reduced sensitivity for minority classes and potentially missed diagnoses in cancer screening applications. We present a comprehensive comparative analysis of Diffusion Models and Deep Convolutional Generative Adversarial Networks (DCGANs), both incorporating modern architectural enhancements including spectral normalization, self-attention mechanisms, and conditional generation, for addressing class imbalance in lung cancer CT classification. Using the IQ-OTH/NCCD dataset comprising 1,097 CT images across normal, benign, and malignant categories with statistical validation across 10 independent runs, we evaluated both approaches through quantitative image quality metrics (Fréchet Inception Distance, Kullback-Leibler divergence, Kernel Inception Distance, and Inception Score) and downstream classification performance. While Diffusion models consistently outperformed DCGANs across most image quality measures, the clinical significance was confirmed through task-based validation. Both generative approaches successfully addressed class imbalance: DCGAN-augmented datasets achieved overall accuracy of 0.9760 ± 0.0116 with benign recall improvement from 0.833 to 0.933, while Diffusion-augmented datasets reached superior performance of 0.9959 ± 0.0068 with perfect benign recall (1.000 ± 0.000). Critically for cancer screening where false negatives carry severe consequences, Diffusion maintained the highest malignant detection sensitivity (0.997 ± 0.008) with substantially lower performance variance, demonstrating more consistent synthetic data quality. These findings establish that while both modern architectures can mitigate class imbalance, Diffusion models' superior recall performance and lower variability position them as the preferred approach for high-stakes clinical applications, demonstrating that ultimate validation must prioritize downstream clinical task performance over image quality metrics alone. • Diffusion models achieve statistically superior performance (99.59% ± 0.68% accuracy, p<0.001) over DCGANs for addressing class imbalance in lung cancer CT classification. • Perfect benign class recall (100% ± 0%) demonstrates diffusion models' effectiveness in detecting underrepresented pathologies critical for comprehensive cancer screening. • Comprehensive statistical validation across 10 independent experimental runs establishes reproducible, robust evidence for generative model selection in clinical applications. • Novel task-centric evaluation framework prioritizes downstream diagnostic performance over image quality metrics, providing generalizable methodology for validating synthetic medical data augmentation.

Authors

Institutions

Publication Details

Journal
Intelligence-Based Medicine
Published
2025-12-22
DOI
https://doi.org/10.1016/j.ibmed.2025.100336
Primary Topic
Lung Cancer Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Diffusion models vs. DCGANs for class-imbalanced lung cancer CT classification: A comparative study

Rajib Saha, Masoud Tabibian, Tahereh Razmpour
Intelligence-Based Medicine
Lung Cancer Diagnosis and Treatment
article

Diffusion models vs. DCGANs for class-imbalanced lung cancer CT classification: A comparative study

Rajib Saha, Masoud Tabibian, Tahereh Razmpour
article en

Abstract

Effective lung cancer detection from CT scans remains critically challenged by class imbalance where benign and normal cases are underrepresented, leading to biased machine learning models with reduced sensitivity for minority classes and potentially missed diagnoses in cancer screening applications. We present a comprehensive comparative analysis of Diffusion Models and Deep Convolutional Generative Adversarial Networks (DCGANs), both incorporating modern architectural enhancements including spectral normalization, self-attention mechanisms, and conditional generation, for addressing class imbalance in lung cancer CT classification. Using the IQ-OTH/NCCD dataset comprising 1,097 CT images across normal, benign, and malignant categories with statistical validation across 10 independent runs, we evaluated both approaches through quantitative image quality metrics (Fréchet Inception Distance, Kullback-Leibler divergence, Kernel Inception Distance, and Inception Score) and downstream classification performance. While Diffusion models consistently outperformed DCGANs across most image quality measures, the clinical significance was confirmed through task-based validation. Both generative approaches successfully addressed class imbalance: DCGAN-augmented datasets achieved overall accuracy of 0.9760 ± 0.0116 with benign recall improvement from 0.833 to 0.933, while Diffusion-augmented datasets reached superior performance of 0.9959 ± 0.0068 with perfect benign recall (1.000 ± 0.000). Critically for cancer screening where false negatives carry severe consequences, Diffusion maintained the highest malignant detection sensitivity (0.997 ± 0.008) with substantially lower performance variance, demonstrating more consistent synthetic data quality. These findings establish that while both modern architectures can mitigate class imbalance, Diffusion models' superior recall performance and lower variability position them as the preferred approach for high-stakes clinical applications, demonstrating that ultimate validation must prioritize downstream clinical task performance over image quality metrics alone. • Diffusion models achieve statistically superior performance (99.59% ± 0.68% accuracy, p<0.001) over DCGANs for addressing class imbalance in lung cancer CT classification. • Perfect benign class recall (100% ± 0%) demonstrates diffusion models' effectiveness in detecting underrepresented pathologies critical for comprehensive cancer screening. • Comprehensive statistical validation across 10 independent experimental runs establishes reproducible, robust evidence for generative model selection in clinical applications. • Novel task-centric evaluation framework prioritizes downstream diagnostic performance over image quality metrics, providing generalizable methodology for validating synthetic medical data augmentation.

Intelligence-Based MedicineVol. 13
University of Nebraska–Lincoln (US)
Quality Education
Openalex Percentile: Top 29%
Lung Cancer Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.