Development of high-Z organic scintillators for modern SPECT imaging and theranostic dosimetry

<ns3:p>Objective. In the fight against cancer, improving the detectors performance is crucial to enhance diagnostic accuracy and optimize therapeutic monitoring. Current clinical SPECT systems predominantly rely on NaI(Tl) crystals, which, despite their advantages, suffer from limited count-rate performance due to long scintillation decay times. Our goal is to address this limitation by developing an innovative class of plastic scintillators doped with high-Z elements. These materials combine the fast timing characteristics of organic scintillators with improved gamma-ray detection efficiency via enhanced photoelectric interaction probability. Methods. Our research has focused on synthesizing novel organic fluorophores to fabricate plastic scintillators doped with high-Z elements with concentrations up to 10%. Moreover, we explored different fabrication techniques, including thermal polymerisation, photoinitiated polymerisation and resin 3D-printing. Results. The resulting prototypes show promising characteristics in terms of optical transparency, dopant homogeneity, light yield and timing performance, reaching levels comparable with commercial standards. Conclusions. These novel scintillators will be at the core of a next-generation SPECT detector, in which the doped scintillators are polymerized directly into the holes of a 3D-printed tungsten collimator, with signal readout performed by tiled CMOS sensors to fully exploit the plastics’ timing properties, and FPGA modules for data pre-processing. Moreover, they will serve for the development of a compact portable dosimeter tailored for metastatic castration-resistant prostate cancer (mCRPC) patients undergoing Lu-177-PSMA-617 radio-metabolic therapy. This device is designed to retrieve the radiopharmaceutical washout curve without requiring multiple SPECT scans, in order to customize the radiopharmaceutical prescription by determining the patient-specific radiometabolic parameters.</ns3:p>

Authors

Institutions

Publication Details

Journal
Bio-Algorithms and Med-Systems
Published
2025-12-22
DOI
https://doi.org/10.5604/01.3001.0055.5412
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of high-Z organic scintillators for modern SPECT imaging and theranostic dosimetry

Viviana Frantellizzi, Leonardo Mattiello, Fabrizio Quattrini, Giuseppe De Vincentis et al.
Bio-Algorithms and Med-Systems
Radiation Detection and Scintillator Technologies
article

Development of high-Z organic scintillators for modern SPECT imaging and theranostic dosimetry

Viviana Frantellizzi, Leonardo Mattiello, Fabrizio Quattrini, Giuseppe De Vincentis, Leonardo Gasparini, Roberto Passerone, A. Schiavi, Enrico Manuzzato, Samane Vahidi, G. Franciosini, M. Garbini, Maria Silvia De Feo, M. Magi, Daniele Rocco, Marco Toppi, A. Sarti, A Burattini, Flavia Allegra, Vincenzo Patera, Michela Marafini, Arianna Vannucci, Johannes Elias Maria Deister, Giacomo Traini, Marina Carruezzo, Mattia Bonuso
article en

Abstract

<ns3:p>Objective. In the fight against cancer, improving the detectors performance is crucial to enhance diagnostic accuracy and optimize therapeutic monitoring. Current clinical SPECT systems predominantly rely on NaI(Tl) crystals, which, despite their advantages, suffer from limited count-rate performance due to long scintillation decay times. Our goal is to address this limitation by developing an innovative class of plastic scintillators doped with high-Z elements. These materials combine the fast timing characteristics of organic scintillators with improved gamma-ray detection efficiency via enhanced photoelectric interaction probability. Methods. Our research has focused on synthesizing novel organic fluorophores to fabricate plastic scintillators doped with high-Z elements with concentrations up to 10%. Moreover, we explored different fabrication techniques, including thermal polymerisation, photoinitiated polymerisation and resin 3D-printing. Results. The resulting prototypes show promising characteristics in terms of optical transparency, dopant homogeneity, light yield and timing performance, reaching levels comparable with commercial standards. Conclusions. These novel scintillators will be at the core of a next-generation SPECT detector, in which the doped scintillators are polymerized directly into the holes of a 3D-printed tungsten collimator, with signal readout performed by tiled CMOS sensors to fully exploit the plastics’ timing properties, and FPGA modules for data pre-processing. Moreover, they will serve for the development of a compact portable dosimeter tailored for metastatic castration-resistant prostate cancer (mCRPC) patients undergoing Lu-177-PSMA-617 radio-metabolic therapy. This device is designed to retrieve the radiopharmaceutical washout curve without requiring multiple SPECT scans, in order to customize the radiopharmaceutical prescription by determining the patient-specific radiometabolic parameters.</ns3:p>

Bio-Algorithms and Med-SystemsVol. 21(Special issue (New Trends))
Roma Tre University (IT), University of Trento (IT), Heidelberg University (DE), Research and Environmental Devices (Italy) (IT), Centro Ricerche Enrico Fermi (IT), Istituto Nazionale di Fisica Nucleare, Sezione di Roma I (IT), Sapienza University of Rome (IT)
Openalex Percentile: Top 27%
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.