From Laboratory to Field: Concurrent Validity of Kinovea’s Linear Kinematics Tracking Tool for Semi-Automated Countermovement Jump Analysis

Affordable high-frame-rate cameras and open-source software, such as Kinovea (ver. 2025.1.0), have expanded the potential for conducting kinematic assessments outside laboratory settings. This study examined the reliability and validity of Kinovea's semi-automated linear kinematics tracking tool by comparing its outputs with those from a 3D marker-based motion capture system (Qualisys). Ten recreationally active male basketball players (x̄ ± SD: age 23.7 ± 1.7 years; height 183 ± 5 cm; body mass 76.8 ± 9.8 kg) performed three CMJ trials, simultaneously recorded using both systems. Reflective markers placed on the shoulder, hip, and knee were tracked in Kinovea by two raters with different levels of experience to extract core CMJ variables (total take-off time and maximum vertical displacement) and complementary variables (eccentric and propulsion duration, and minimum vertical displacement). Inter-rater reliability and concurrent validity were evaluated using intraclass correlation coefficients (ICCs), coefficients of variation (CV%), standard error of measurement (SEM), and Bland-Altman analysis. Results showed excellent inter-rater reliability (ICC = 0.73-0.99) across all markers, with the hip and knee demonstrating the highest consistency. Strong validity relative to Qualisys was observed for both raters (ICC = 0.68-0.99; r > 0.80), with small systematic biases primarily in temporal variables. Collectively, these findings demonstrate that Kinovea's semi-automated 2D analysis yields reliable and valid CMJ measurements comparable to 3D motion capture, even for less experienced users. As a free and easily deployable tool, it offers a widely accessible alternative for field-based performance monitoring and applied biomechanics research where laboratory-grade equipment is not available.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-12-19
DOI
https://doi.org/10.3390/s26010024
Primary Topic
Sports injuries and prevention
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

From Laboratory to Field: Concurrent Validity of Kinovea’s Linear Kinematics Tracking Tool for Semi-Automated Countermovement Jump Analysis

Hrvoje Brkić, Damir Sekulić, Branislav Božović, Olivera M. Knežević et al.
Sensors
Sports injuries and prevention
article

From Laboratory to Field: Concurrent Validity of Kinovea’s Linear Kinematics Tracking Tool for Semi-Automated Countermovement Jump Analysis

Hrvoje Brkić, Damir Sekulić, Branislav Božović, Olivera M. Knežević, Dragan M. Mirkov, Lucija Faj, Jelena Aleksić
article en

Abstract

Affordable high-frame-rate cameras and open-source software, such as Kinovea (ver. 2025.1.0), have expanded the potential for conducting kinematic assessments outside laboratory settings. This study examined the reliability and validity of Kinovea's semi-automated linear kinematics tracking tool by comparing its outputs with those from a 3D marker-based motion capture system (Qualisys). Ten recreationally active male basketball players (x̄ ± SD: age 23.7 ± 1.7 years; height 183 ± 5 cm; body mass 76.8 ± 9.8 kg) performed three CMJ trials, simultaneously recorded using both systems. Reflective markers placed on the shoulder, hip, and knee were tracked in Kinovea by two raters with different levels of experience to extract core CMJ variables (total take-off time and maximum vertical displacement) and complementary variables (eccentric and propulsion duration, and minimum vertical displacement). Inter-rater reliability and concurrent validity were evaluated using intraclass correlation coefficients (ICCs), coefficients of variation (CV%), standard error of measurement (SEM), and Bland-Altman analysis. Results showed excellent inter-rater reliability (ICC = 0.73-0.99) across all markers, with the hip and knee demonstrating the highest consistency. Strong validity relative to Qualisys was observed for both raters (ICC = 0.68-0.99; r > 0.80), with small systematic biases primarily in temporal variables. Collectively, these findings demonstrate that Kinovea's semi-automated 2D analysis yields reliable and valid CMJ measurements comparable to 3D motion capture, even for less experienced users. As a free and easily deployable tool, it offers a widely accessible alternative for field-based performance monitoring and applied biomechanics research where laboratory-grade equipment is not available.

SensorsVol. 26(1)
University of Belgrade (RS), University of Osijek (HR), University of Split (HR)
Openalex Percentile: Top 34%
Sports injuries and prevention
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.