Noninvasive Outflow Graft Flow Waveform Assessment Using Echocardiography and the HeartMate 3 Snoopy: A Mock Loop Study

The instantaneous left ventricular assist device (LVAD) flow waveform of the HeartWare ventricular assist device (HVAD) device was previously used to assess hemodynamic parameters, which is not possible with the HeartMate 3 (HM3). The purpose of this study was to assess the ability of pulsed wave Doppler interrogation of the outflow graft (PWOG) and of a novel noninvasive pump data acquisition system (HM3 Snoopy) to obtain noninvasive flow waveforms (NIFW) and to determine whether these predict hemodynamic changes. The study was conducted using a fluid-filled, biventricular failure mock loop model with a flow probe (FP) placed around the distal outflow. Five different pump speeds, two distinct hematocrits, and preload and afterload changes were used to create 56 unique hemodynamic states. Noninvasive flow waveform parameters were assessed for correlation against FP-derived parameters. Subsequently, NIFW parameters were assessed for their predictive capabilities for preload and afterload changes. There was moderate correlation between NIFW and FP-derived systolic waveform parameters (r range: 0.43-0.81), and strong correlation for diastolic parameters (r range: 0.87-0.99). Flow waveform amplitude as obtained by echocardiography was the best preload predictor (r2 = 0.67). A multiple linear regression model of NIFW parameters provided adequate prediction of afterload (r2 = 0.85). HeartMate 3 Snoopy and PWOG are promising tools for generating flow waveform surrogates and detecting hemodynamic changes.

Authors

Institutions

Publication Details

Journal
ASAIO Journal
Published
2025-12-22
DOI
https://doi.org/10.1097/mat.0000000000002610
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Noninvasive Outflow Graft Flow Waveform Assessment Using Echocardiography and the HeartMate 3 Snoopy: A Mock Loop Study

G Widhalm, K. Muthiah, D. Robson, Ricardo Deveza et al.
ASAIO Journal
Mechanical Circulatory Support Devices
article

Noninvasive Outflow Graft Flow Waveform Assessment Using Echocardiography and the HeartMate 3 Snoopy: A Mock Loop Study

G Widhalm, K. Muthiah, D. Robson, Ricardo Deveza, S. Barua, Mina A. Saweris, Thomas Schlöglhofer, Pankaj Jain, T. Abart, Christian F. Said, Christopher Hayward
article en

Abstract

The instantaneous left ventricular assist device (LVAD) flow waveform of the HeartWare ventricular assist device (HVAD) device was previously used to assess hemodynamic parameters, which is not possible with the HeartMate 3 (HM3). The purpose of this study was to assess the ability of pulsed wave Doppler interrogation of the outflow graft (PWOG) and of a novel noninvasive pump data acquisition system (HM3 Snoopy) to obtain noninvasive flow waveforms (NIFW) and to determine whether these predict hemodynamic changes. The study was conducted using a fluid-filled, biventricular failure mock loop model with a flow probe (FP) placed around the distal outflow. Five different pump speeds, two distinct hematocrits, and preload and afterload changes were used to create 56 unique hemodynamic states. Noninvasive flow waveform parameters were assessed for correlation against FP-derived parameters. Subsequently, NIFW parameters were assessed for their predictive capabilities for preload and afterload changes. There was moderate correlation between NIFW and FP-derived systolic waveform parameters (r range: 0.43-0.81), and strong correlation for diastolic parameters (r range: 0.87-0.99). Flow waveform amplitude as obtained by echocardiography was the best preload predictor (r2 = 0.67). A multiple linear regression model of NIFW parameters provided adequate prediction of afterload (r2 = 0.85). HeartMate 3 Snoopy and PWOG are promising tools for generating flow waveform surrogates and detecting hemodynamic changes.

ASAIO Journal
Victor Chang Cardiac Research Institute (AU), Royal Prince Alfred Hospital (AU), UNSW Sydney (AU), St Vincent's Hospital Sydney (AU), Ludwig Boltzmann Institute for Cancer Research (AT), Ludwig Boltzmann Institute for Digital Health and Prevention (AT), Medical University of Vienna (AT)
Openalex Percentile: Top 43%
Mechanical Circulatory Support Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.