Experimental performance analysis of concrete-filled steel column to concrete-filled steel beam connections

Existing literature and practical engineering practice have comprehensively examined the behaviour of concrete-filled steel tubular (CFST) columns, CFST beams, and their associated connection systems involving either steel or reinforced concrete (RC) beams. Despite these advancements, limited research has focused on the direct beam–column interaction in fully CFST-to-CFST connection configurations. The absence of established design specifications and systematic experimental evidence has hindered the reliable adoption of such connections in structural applications. This feasibility study addresses this knowledge gap by conducting an integrated theoretical and experimental investigation into the structural performance of moment-resisting connections between CFST columns—locally strengthened with internal stiffening plates and configured with external bolted flange connections—and CFST beams of matching geometry. To provide a meaningful benchmark, a comparable hollow steel column–steel beam connection with identical cross-sectional dimensions and bolt arrangements was also evaluated. The experimental setup involved cyclic loading tests designed to capture load–rotation behaviour, quantify flexural stiffness, and identify critical limit states governing connection performance. Detailed measurements of moment–displacement response, local deformation patterns, and strain distribution were collected to assess connection rigidity, load-transfer mechanisms, and potential vulnerability to local buckling. The resulting data allowed for direct comparison between the proposed CFST-to-CFST connection configuration and the hollow steel reference specimen, enabling a clearer understanding of the composite action and confinement effects provided by the infilled concrete. The findings contribute foundational evidence for the feasibility of those moment connections and offer preliminary insights to support future analytical modelling, design recommendations, and full-scale implementation.

Authors

Publication Details

Journal
Challenge Journal of Concrete Research Letters
Published
2025-12-22
DOI
https://doi.org/10.20528/cjcrl.2025.04.004
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental performance analysis of concrete-filled steel column to concrete-filled steel beam connections

Serdar Çarbaş, Sadrettin Sancıoğlu, Abdulkerim İlgün
Challenge Journal of Concrete Research Letters
Structural Load-Bearing Analysis
article

Experimental performance analysis of concrete-filled steel column to concrete-filled steel beam connections

Serdar Çarbaş, Sadrettin Sancıoğlu, Abdulkerim İlgün
article en

Abstract

Existing literature and practical engineering practice have comprehensively examined the behaviour of concrete-filled steel tubular (CFST) columns, CFST beams, and their associated connection systems involving either steel or reinforced concrete (RC) beams. Despite these advancements, limited research has focused on the direct beam–column interaction in fully CFST-to-CFST connection configurations. The absence of established design specifications and systematic experimental evidence has hindered the reliable adoption of such connections in structural applications. This feasibility study addresses this knowledge gap by conducting an integrated theoretical and experimental investigation into the structural performance of moment-resisting connections between CFST columns—locally strengthened with internal stiffening plates and configured with external bolted flange connections—and CFST beams of matching geometry. To provide a meaningful benchmark, a comparable hollow steel column–steel beam connection with identical cross-sectional dimensions and bolt arrangements was also evaluated. The experimental setup involved cyclic loading tests designed to capture load–rotation behaviour, quantify flexural stiffness, and identify critical limit states governing connection performance. Detailed measurements of moment–displacement response, local deformation patterns, and strain distribution were collected to assess connection rigidity, load-transfer mechanisms, and potential vulnerability to local buckling. The resulting data allowed for direct comparison between the proposed CFST-to-CFST connection configuration and the hollow steel reference specimen, enabling a clearer understanding of the composite action and confinement effects provided by the infilled concrete. The findings contribute foundational evidence for the feasibility of those moment connections and offer preliminary insights to support future analytical modelling, design recommendations, and full-scale implementation.

Challenge Journal of Concrete Research LettersVol. 16(4)
Sustainable cities and communities
Openalex Percentile: Top 38%
Structural Load-Bearing Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Experimental performance analysis of concrete-filled steel column to concrete-filled steel beam connections — Serdar Çarbaş, Sadrettin Sancıoğlu, et al. · Challenge Journal of Concrete Research Letters (2025) | TGRS Research Map | TGRS