Accurate detection of Cd (II) based on His-Pd@Apt/PANI@Au-modified needle electrochemical ratiometric/colorimetric dual-mode sensor combined with a WeChat mini program

Heavy metal cadmium (Cd (II)) contamination in aquatic products poses severe health risks, necessitating rapid, accurate, and portable detection methods. Traditional electrochemical sensors often suffer from background interference and low accuracy, especially when utilizing stainless steel acupuncture needles as electrodes. Single-signal systems are prone to environmental fluctuations, limiting reliability. Thus, there is an urgent need for a sensitive, low-cost, and visual sensor that integrates dual detection modes for on-site analysis of Cd (II). We report a novel ratiometric/colorimetric dual-mode aptamer sensor based on a polyaniline-gold nanocomposite (PANI@Au)-modified acupuncture needle. This platform uses PANI's peak at -0.9 V as an internal reference and His-Pd@aptamer's peak at -0.2 V as a detection signal, enabling ratiometric electrochemical quantification. In parallel, His-Pd nanoparticles catalyze the oxidation of TMB to produce a blue color, allowing visual detection with a limit of 3.10 × 10<sup>-2</sup> ng/L. RGB values are analyzed by a smartphone and WeChat mini-program for rapid result output. The electrochemical and colorimetric modes demonstrated excellent sensitivity (LOD: 3.40 × 10<sup>-2</sup> ng/L electrochemical; 1.06 × 10<sup>-1</sup> ng/L RGB-based) and linear range of 10<sup>1</sup>-10<sup>8</sup> ng/L. The sensor showed strong selectivity, stability, and successful application in detecting Cd (II) in fish, shrimp, and scallop samples with high recovery rates. This is the first report of a needle-based ratiometric/colorimetric aptamer sensor that enables both electrochemical quantification and smartphone-based visual detection of Cd (II). The device supports rapid, on-site, and low-skill operation with sub-100 μL samples, demonstrating its potential for real-time monitoring of heavy metal contamination in aquatic food safety.

Authors

Institutions

Publication Details

Journal
Talanta
Published
2025-12-22
DOI
https://doi.org/10.1016/j.talanta.2025.129287
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accurate detection of Cd (II) based on His-Pd@Apt/PANI@Au-modified needle electrochemical ratiometric/colorimetric dual-mode sensor combined with a WeChat mini program

Luting Yan, Yanyan Zhang, Qi Guo, Yuhao Zhang et al.
Talanta
Advanced biosensing and bioanalysis techniques
article

Accurate detection of Cd (II) based on His-Pd@Apt/PANI@Au-modified needle electrochemical ratiometric/colorimetric dual-mode sensor combined with a WeChat mini program

Luting Yan, Yanyan Zhang, Qi Guo, Yuhao Zhang, Lei Tian, Yanyan Zhang
article en

Abstract

Heavy metal cadmium (Cd (II)) contamination in aquatic products poses severe health risks, necessitating rapid, accurate, and portable detection methods. Traditional electrochemical sensors often suffer from background interference and low accuracy, especially when utilizing stainless steel acupuncture needles as electrodes. Single-signal systems are prone to environmental fluctuations, limiting reliability. Thus, there is an urgent need for a sensitive, low-cost, and visual sensor that integrates dual detection modes for on-site analysis of Cd (II). We report a novel ratiometric/colorimetric dual-mode aptamer sensor based on a polyaniline-gold nanocomposite (PANI@Au)-modified acupuncture needle. This platform uses PANI's peak at -0.9 V as an internal reference and His-Pd@aptamer's peak at -0.2 V as a detection signal, enabling ratiometric electrochemical quantification. In parallel, His-Pd nanoparticles catalyze the oxidation of TMB to produce a blue color, allowing visual detection with a limit of 3.10 × 10<sup>-2</sup> ng/L. RGB values are analyzed by a smartphone and WeChat mini-program for rapid result output. The electrochemical and colorimetric modes demonstrated excellent sensitivity (LOD: 3.40 × 10<sup>-2</sup> ng/L electrochemical; 1.06 × 10<sup>-1</sup> ng/L RGB-based) and linear range of 10<sup>1</sup>-10<sup>8</sup> ng/L. The sensor showed strong selectivity, stability, and successful application in detecting Cd (II) in fish, shrimp, and scallop samples with high recovery rates. This is the first report of a needle-based ratiometric/colorimetric aptamer sensor that enables both electrochemical quantification and smartphone-based visual detection of Cd (II). The device supports rapid, on-site, and low-skill operation with sub-100 μL samples, demonstrating its potential for real-time monitoring of heavy metal contamination in aquatic food safety.

TalantaVol. 301
Shandong University of Technology (CN)
Life below water
Openalex Percentile: Top 37%
Advanced biosensing and bioanalysis techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Accurate detection of Cd (II) based on His-Pd@Apt/PANI@Au-modified needle electrochemical ratiometric/colorimetric dual-mode sensor combined with a WeChat mini program — Luting Yan, Yanyan Zhang, et al. · Talanta (2025) | TGRS Research Map | TGRS