Shoulder Muscle Strength Assessment: A Comparative Study of Hand-Held Dynamometers and Load Cell Measurements

Accurate measurement of shoulder muscle strength is important for diagnosis, treatment planning, and monitoring recovery. Hand-held dynamometers (HHDs) are widely used in clinical practice but are affected by operator strength, patient positioning, and device stabilization, particularly under high-load conditions. No previous study has directly compared HHD measurements with a reference load cell in a rigid serial configuration or evaluated the effect of different load cell signal processing strategies on the final strength value. The aim of this study was to compare HHD measurements with those obtained from a reference load cell in a rigid serial configuration and to assess how different signal processing strategies applied to load cell data influence the final outcomes. A custom 3D-printed support was developed to align a commercial HHD and a load cell in series, ensuring identical loading conditions. Measurements were performed under two conditions: (i) application of known weights (9.81–98.10 N) and (ii) standardized strength tasks in five healthy volunteers. Agreement between instruments was evaluated using Bland–Altman analysis and Root Mean Square Error (RMSE). In static validation (i.e., experiments applying know weights), the load cell demonstrated stable performance, with standard deviations below 1% of the applied load. HHD variability increased with load, with RMSE rising from 0.55 N at 9.81 N to 5.06 N at 98.10 N. In human testing, the HHD consistently underestimated muscle strength compared with the load cell, with mean differences ranging from −15 N to −19 N, over exerted force ranges of approximately 20–90 N. Overall, the load cell provided stable reference measurements, while the choice of signal processing strategy influenced the results: plateau-phase analysis tended to reduce systematic bias but did not consistently narrow the limits of agreement.

Authors

Institutions

Publication Details

Journal
Instruments
Published
2025-12-20
DOI
https://doi.org/10.3390/instruments10010002
Primary Topic
Shoulder Injury and Treatment
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Shoulder Muscle Strength Assessment: A Comparative Study of Hand-Held Dynamometers and Load Cell Measurements

Emiliano Schena, Arianna Carnevale, Pieter P. R. N. d’Hooghe, Alessandro de Sire et al.
Instruments
Shoulder Injury and Treatment
article

Shoulder Muscle Strength Assessment: A Comparative Study of Hand-Held Dynamometers and Load Cell Measurements

Emiliano Schena, Arianna Carnevale, Pieter P. R. N. d’Hooghe, Alessandro de Sire, Michele Mercurio, Carla Antonacci, Rocco Papalia, Umile Giuseppe Longo, Letizia Mancini
article en

Abstract

Accurate measurement of shoulder muscle strength is important for diagnosis, treatment planning, and monitoring recovery. Hand-held dynamometers (HHDs) are widely used in clinical practice but are affected by operator strength, patient positioning, and device stabilization, particularly under high-load conditions. No previous study has directly compared HHD measurements with a reference load cell in a rigid serial configuration or evaluated the effect of different load cell signal processing strategies on the final strength value. The aim of this study was to compare HHD measurements with those obtained from a reference load cell in a rigid serial configuration and to assess how different signal processing strategies applied to load cell data influence the final outcomes. A custom 3D-printed support was developed to align a commercial HHD and a load cell in series, ensuring identical loading conditions. Measurements were performed under two conditions: (i) application of known weights (9.81–98.10 N) and (ii) standardized strength tasks in five healthy volunteers. Agreement between instruments was evaluated using Bland–Altman analysis and Root Mean Square Error (RMSE). In static validation (i.e., experiments applying know weights), the load cell demonstrated stable performance, with standard deviations below 1% of the applied load. HHD variability increased with load, with RMSE rising from 0.55 N at 9.81 N to 5.06 N at 98.10 N. In human testing, the HHD consistently underestimated muscle strength compared with the load cell, with mean differences ranging from −15 N to −19 N, over exerted force ranges of approximately 20–90 N. Overall, the load cell provided stable reference measurements, while the choice of signal processing strategy influenced the results: plateau-phase analysis tended to reduce systematic bias but did not consistently narrow the limits of agreement.

InstrumentsVol. 10(1)
Università Campus Bio-Medico (IT), Magna Graecia University (IT), Qatar Orthopaedic and Sports Medicine Hospital (QA), Institute for Musculoskeletal Health (AU), Campus Bio Medico University Hospital (IT)
Ministero della Salute
Good health and well-being
Openalex Percentile: Top 27%
Shoulder Injury and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.