Liquid-Nitrogen-Cooled <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" display="inline"> <mml:msup> <mml:mo></mml:mo> <mml:mn>40</mml:mn> </mml:msup> <mml:msup> <mml:mi>Ca</mml:mi> <mml:mo>+</mml:mo> </mml:msup> </mml:math> Ion Optical Clock
We report a single-ion optical clock based on the 4S_{1/2}→3D_{5/2} transition of the ^{40}Ca^{+} ion, operated in a liquid nitrogen cryogenic environment, achieving a total systematic uncertainty of 4.4×10^{-19}. We employ a refined temperature evaluation scheme to reduce the frequency uncertainty due to blackbody radiation, and 3D sideband cooling to minimize the second-order Doppler shift. We have precisely determined the average Zeeman coefficient of the ^{40}Ca^{+} clock transition to be 14.345(15) Hz/mT^{2}, thereby significantly reducing the quadratic Zeeman shift uncertainty. Moreover, the cryogenic environment enables the lowest reported heating rate due to ambient electric field noise in trapped-ion optical clocks.
Authors
- Ting Yun Shi
- Yuzhuo Wang
- Hui-Li Han (ORCID: https://orcid.org/0000-0002-8391-3731)
- Li Yan Tang
- Kelin Gao
- Guan Hua
- Anonymous
- Hua-qing Zhang
- Zi-xiao Ma
- Ru-ming Hu
- Yao Huang
Institutions
- University of Science and Technology of China (CN)
- Chinese Academy of Sciences (CN)
- University of Chinese Academy of Sciences (CN)
- Wuhan Institute of Technology (CN)
Publication Details
- Journal
- Physical Review Letters
- Published
- 2025-12-22
- DOI
- https://doi.org/10.1103/vngc-c1xv
- Citations
- 2
- Primary Topic
- Advanced Frequency and Time Standards
- Type
- article
- Field-Weighted Citation Impact
- 2.49