Real-time detection of short-circuit faults in power systems using LSTM autoencoder

This paper presents a real-time detection method for short-circuit faults in meshed power networks, based on a Long Short-Term Memory (LSTM) autoencoder. The objective is to quickly and accurately identify both simple faults (single-phase, double-phase, three-phase), hybrid faults, and triple faults characterized by the simultaneous occurrence of several types of faults on different network lines. Simulations were carried out on an IEEE 9-bus system modeled in MATLAB/Simulink, covering various scenarios: faults on a single line, on two lines, and on three lines simultaneously. The results obtained show an immediate reaction of the model to disturbances, reflected by a marked increase in the loss function at the time of the incident. The system also demonstrated its ability to detect the indirect impact of faults on neighboring lines, reflecting the propagation of electrical imbalances throughout the network. These performances confirm the effectiveness and robustness of the LSTM autoencoder for intelligent, fine, and adaptive monitoring of modern power networks, fully meeting the requirements of real-time protection systems.

Authors

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2025-12-19
DOI
https://doi.org/10.1051/e3sconf/202568000054/pdf
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Real-time detection of short-circuit faults in power systems using LSTM autoencoder

Slaoui Fouad Hasnaoui, Polster Kader Mbakob Ndagoua
Springer Link (Chiba Institute of Technology)
Power Systems Fault Detection
article

Real-time detection of short-circuit faults in power systems using LSTM autoencoder

Slaoui Fouad Hasnaoui, Polster Kader Mbakob Ndagoua
article en

Abstract

This paper presents a real-time detection method for short-circuit faults in meshed power networks, based on a Long Short-Term Memory (LSTM) autoencoder. The objective is to quickly and accurately identify both simple faults (single-phase, double-phase, three-phase), hybrid faults, and triple faults characterized by the simultaneous occurrence of several types of faults on different network lines. Simulations were carried out on an IEEE 9-bus system modeled in MATLAB/Simulink, covering various scenarios: faults on a single line, on two lines, and on three lines simultaneously. The results obtained show an immediate reaction of the model to disturbances, reflected by a marked increase in the loss function at the time of the incident. The system also demonstrated its ability to detect the indirect impact of faults on neighboring lines, reflecting the propagation of electrical imbalances throughout the network. These performances confirm the effectiveness and robustness of the LSTM autoencoder for intelligent, fine, and adaptive monitoring of modern power networks, fully meeting the requirements of real-time protection systems.

Springer Link (Chiba Institute of Technology)
Openalex Percentile: Top 38%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Real-time detection of short-circuit faults in power systems using LSTM autoencoder — Slaoui Fouad Hasnaoui, Polster Kader Mbakob Ndagoua · Springer Link (Chiba Institute of Technology) (2025) | TGRS Research Map | TGRS