Improvement of the system for reporting the state of the electrified railway contact line

Ensuring the stable and reliable operation of electrified railways requires continuous monitoring of the overhead contact line (CL), whose mechanical displacement under wind loads can lead to interruptions in power transmission, pantograph detachment, and safety hazards. Traditional inspection and monitoring systems are limited in responsiveness and cannot provide real-time information about the dynamic state of the CL. This study presents an improved contact line deviation reporting system based on distributed Signal Processing and Transmission Modules (SPTM) and Signal Reception Modules (SRM) connected through a GSM wireless communication network. Each vibration sensor installed on the catenary wire continuously measures the displacement amplitude, converts the analog signal into digital form, and transmits it to the dispatcher or driver in real time. The developed modules were implemented using microcontrollers with embedded wireless interfaces, allowing autonomous operation powered by solar-assisted batteries and ensuring electromagnetic protection under high-voltage (25 kV) conditions. Field experiments were carried out on an electrified railway test section near the Tashkent depot to evaluate the system’s performance in real environmental conditions – including wind speeds of 5-18 m/s, ambient temperatures from –10 °C to +38 °C, and during snow and rain. The results confirmed stable data transmission up to 1 km distance with signal delay below 0.8 s and detection accuracy above 95 %. The proposed system thus enables real-time monitoring, automatic warning, and high reliability of communication even under harsh weather conditions, significantly improving the safety and efficiency of train operation. The novelty of this work lies in the practical validation of a GSM-based monitoring network for contact line deviation detection that integrates autonomous power supply, environmental robustness, and real-field reliability testing – aspects that are rarely demonstrated in previous studies.

Authors

Publication Details

Journal
Vibroengineering PROCEDIA
Published
2025-12-22
DOI
https://doi.org/10.21595/vp.2025.25647
Primary Topic
Electrical Contact Performance and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improvement of the system for reporting the state of the electrified railway contact line

Iroda Abduazimova, Islom Karimov, Sayfiddin Norjigitov, Sulton Amirov
Vibroengineering PROCEDIA
Electrical Contact Performance and Analysis
article

Improvement of the system for reporting the state of the electrified railway contact line

Iroda Abduazimova, Islom Karimov, Sayfiddin Norjigitov, Sulton Amirov
article en

Abstract

Ensuring the stable and reliable operation of electrified railways requires continuous monitoring of the overhead contact line (CL), whose mechanical displacement under wind loads can lead to interruptions in power transmission, pantograph detachment, and safety hazards. Traditional inspection and monitoring systems are limited in responsiveness and cannot provide real-time information about the dynamic state of the CL. This study presents an improved contact line deviation reporting system based on distributed Signal Processing and Transmission Modules (SPTM) and Signal Reception Modules (SRM) connected through a GSM wireless communication network. Each vibration sensor installed on the catenary wire continuously measures the displacement amplitude, converts the analog signal into digital form, and transmits it to the dispatcher or driver in real time. The developed modules were implemented using microcontrollers with embedded wireless interfaces, allowing autonomous operation powered by solar-assisted batteries and ensuring electromagnetic protection under high-voltage (25 kV) conditions. Field experiments were carried out on an electrified railway test section near the Tashkent depot to evaluate the system’s performance in real environmental conditions – including wind speeds of 5-18 m/s, ambient temperatures from –10 °C to +38 °C, and during snow and rain. The results confirmed stable data transmission up to 1 km distance with signal delay below 0.8 s and detection accuracy above 95 %. The proposed system thus enables real-time monitoring, automatic warning, and high reliability of communication even under harsh weather conditions, significantly improving the safety and efficiency of train operation. The novelty of this work lies in the practical validation of a GSM-based monitoring network for contact line deviation detection that integrates autonomous power supply, environmental robustness, and real-field reliability testing – aspects that are rarely demonstrated in previous studies.

Vibroengineering PROCEDIAVol. 60
Affordable and clean energy
Openalex Percentile: Top 46%
Electrical Contact Performance and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.