Augmented reality-based portable navigation improves accuracy of cup placement in total hip arthroplasty with a short learning curve

Malpositioning of the acetabular cup in total hip arthroplasty (THA) can cause complications including dislocation, wear, and aseptic loosening. Although computed tomography (CT)-based navigation systems have improved THA accuracy, the high cost and complexity of these systems have hindered their widespread use. Therefore, this study investigated the accuracy and learning curve of an augmented reality (AR)-based portable navigation system. This retrospective study analyzed 106 hips in 87 patients who underwent primary THA using an AR-based portable navigation system between July 2023 and December 2024. A single surgeon performed all surgeries. The accuracy of the intraoperative navigation records for cup inclination and anteversion was assessed by comparing them with postoperative CT-based measurements. Absolute error values exceeding 5° and 10° were defined as outliers > 5° and > 10°, respectively. Receiver operating characteristic (ROC) analysis was used to evaluate the learning curve, and multivariate logistic regression identified risk factors associated with cases classified as outliers (> 5°). The mean absolute errors between the navigation records and postoperative measurements were 2.2° for inclination and 3.8° for anteversion. Outliers > 5° were observed in 31% of cases, while outliers > 10° were rare (2.8%). No dislocations or revisions occurred within six months. Learning curve analysis showed consistent accuracy in the initial cases. The only significant predictor of navigation error was intraoperative posterior pelvic tilt change (odds ratio 1.13, p = 0.04). Body mass index and subcutaneous fat thickness were not significantly different. The AR-based portable navigation provided highly accurate acetabular cup placement without a learning curve. However, excessive intraoperative posterior pelvic tilt increased the risk of anteversion overestimation, highlighting the need for intraoperative pelvic position management.

Authors

Institutions

Publication Details

Journal
BMC Musculoskeletal Disorders
Published
2025-12-22
DOI
https://doi.org/10.1186/s12891-025-09446-6
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Augmented reality-based portable navigation improves accuracy of cup placement in total hip arthroplasty with a short learning curve

T Tachibana, Ryusuke Saito, Takahisa Ogawa, Hiroki Katagiri et al.
BMC Musculoskeletal Disorders
Orthopaedic implants and arthroplasty
article

Augmented reality-based portable navigation improves accuracy of cup placement in total hip arthroplasty with a short learning curve

T Tachibana, Ryusuke Saito, Takahisa Ogawa, Hiroki Katagiri, Tetsuya Jinno
article en

Abstract

Malpositioning of the acetabular cup in total hip arthroplasty (THA) can cause complications including dislocation, wear, and aseptic loosening. Although computed tomography (CT)-based navigation systems have improved THA accuracy, the high cost and complexity of these systems have hindered their widespread use. Therefore, this study investigated the accuracy and learning curve of an augmented reality (AR)-based portable navigation system. This retrospective study analyzed 106 hips in 87 patients who underwent primary THA using an AR-based portable navigation system between July 2023 and December 2024. A single surgeon performed all surgeries. The accuracy of the intraoperative navigation records for cup inclination and anteversion was assessed by comparing them with postoperative CT-based measurements. Absolute error values exceeding 5° and 10° were defined as outliers > 5° and > 10°, respectively. Receiver operating characteristic (ROC) analysis was used to evaluate the learning curve, and multivariate logistic regression identified risk factors associated with cases classified as outliers (> 5°). The mean absolute errors between the navigation records and postoperative measurements were 2.2° for inclination and 3.8° for anteversion. Outliers > 5° were observed in 31% of cases, while outliers > 10° were rare (2.8%). No dislocations or revisions occurred within six months. Learning curve analysis showed consistent accuracy in the initial cases. The only significant predictor of navigation error was intraoperative posterior pelvic tilt change (odds ratio 1.13, p = 0.04). Body mass index and subcutaneous fat thickness were not significantly different. The AR-based portable navigation provided highly accurate acetabular cup placement without a learning curve. However, excessive intraoperative posterior pelvic tilt increased the risk of anteversion overestimation, highlighting the need for intraoperative pelvic position management.

BMC Musculoskeletal DisordersVol. 26(1)
Japan Sport Council (JP), Institute for Health Economics and Policy (JP), Dokkyo Medical University Saitama Medical Center (JP), Saitama Red Cross Hospital (JP)
Japan Society for the Promotion of Science
Openalex Percentile: Top 27%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.