Using synthetic data for pretraining partial discharge detection in overhead transmission lines

Accurate detection of partial discharges (PDs) in medium-voltage overhead transmission lines is critical for preemptive maintenance and avoiding costly outages, yet it is challenged by scarce labeled data and pervasive electromagnetic interference. This paper investigates a hybrid simulation-and-data-driven framework in which synthetically generated PD signals are used to pretrain deep neural networks and are subsequently fine-tuned on a limited set of real overhead-line measurements. The synthetic pipeline systematically varies PD repetition rates, amplitude distributions, vegetation-contact scenarios, and noise conditions, producing diverse time-series and spectrogram-like representations that approximate real operating environments. We conduct a comprehensive ablation study across multiple architectures-Convolutional Neural Networks (CNNs), a Vision Transformer (ViT), and a Long Short-Term Memory (LSTM) network-and analyze their sensitivity to granular sweeps of synthetic-data parameters. CNN-based models decisively outperform ViT and LSTM counterparts on the spectrogram-based classification task, while ViT and LSTM fail to learn meaningful representation. For the successful CNNs, pretraining on carefully parameterized synthetic datasets-particularly those reflecting higher PD activity, such as our Datasets 3 and 4-consistently improves downstream performance on real data, boosting the Matthews Correlation Coefficient (MCC) on imbalanced, cost-sensitive test sets by roughly 10-20% compared with training from scratch. At the same time, we show that poorly aligned synthetic data can degrade generalization, underscoring the need for accurate noise calibration and domain-aligned simulation. Overall, the results confirm that (i) architectural choice is pivotal for PD detection in overhead lines and (ii) well-designed synthetic data is a powerful, practical lever for achieving reliable and cost-effective PD monitoring when real labeled data are limited.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-12-22
DOI
https://doi.org/10.1038/s41598-025-32642-2
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Using synthetic data for pretraining partial discharge detection in overhead transmission lines

Jiří Dvorský, Ondřej Kabot, Lukáš Klein, Lukáš Prokop et al.
Scientific Reports
High voltage insulation and dielectric phenomena
article

Using synthetic data for pretraining partial discharge detection in overhead transmission lines

Jiří Dvorský, Ondřej Kabot, Lukáš Klein, Lukáš Prokop, Jan Fulneček
article en

Abstract

Accurate detection of partial discharges (PDs) in medium-voltage overhead transmission lines is critical for preemptive maintenance and avoiding costly outages, yet it is challenged by scarce labeled data and pervasive electromagnetic interference. This paper investigates a hybrid simulation-and-data-driven framework in which synthetically generated PD signals are used to pretrain deep neural networks and are subsequently fine-tuned on a limited set of real overhead-line measurements. The synthetic pipeline systematically varies PD repetition rates, amplitude distributions, vegetation-contact scenarios, and noise conditions, producing diverse time-series and spectrogram-like representations that approximate real operating environments. We conduct a comprehensive ablation study across multiple architectures-Convolutional Neural Networks (CNNs), a Vision Transformer (ViT), and a Long Short-Term Memory (LSTM) network-and analyze their sensitivity to granular sweeps of synthetic-data parameters. CNN-based models decisively outperform ViT and LSTM counterparts on the spectrogram-based classification task, while ViT and LSTM fail to learn meaningful representation. For the successful CNNs, pretraining on carefully parameterized synthetic datasets-particularly those reflecting higher PD activity, such as our Datasets 3 and 4-consistently improves downstream performance on real data, boosting the Matthews Correlation Coefficient (MCC) on imbalanced, cost-sensitive test sets by roughly 10-20% compared with training from scratch. At the same time, we show that poorly aligned synthetic data can degrade generalization, underscoring the need for accurate noise calibration and domain-aligned simulation. Overall, the results confirm that (i) architectural choice is pivotal for PD detection in overhead lines and (ii) well-designed synthetic data is a powerful, practical lever for achieving reliable and cost-effective PD monitoring when real labeled data are limited.

Scientific ReportsVol. 15(1)
VSB - Technical University of Ostrava (CZ)
European Commission, Ostravská Univerzita v Ostravě
Openalex Percentile: Top 49%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.