The Current State of Mock Circulatory Loop Applications in Aortic and Cardiovascular Research: A Scoping Review

<b>Background</b>: Mock circulatory loops (MCLs) are benchtop experimental platforms that reproduce key features of the human cardiovascular system, providing a safe, controlled, and reproducible environment for haemodynamic investigation. This scoping review aims to systematically map the current landscape of MCLs used for aortic simulation and identify major areas of application. <b>Methods</b>: A systematic search of PubMed, Scopus, and Web of Science identified original studies employing MCLs for aortic simulation. Eligible studies were categorized into predefined themes: (I) (bio)mechanical aortic characterization, (II) hemodynamics, (III) device testing, (IV) diagnostics, and (V) training. Data on MCL configurations, aortic models, and study objectives were synthesized narratively. <b>Results</b>: Eighty-four studies met the inclusion criteria. Twenty-five investigated aortic biomechanics, 23 hemodynamics, 22 device or product testing, 13 validated diagnostic imaging techniques, and one training application. Models included porcine (<i>n</i> = 22), human cadaveric (<i>n</i> = 7), canine (<i>n</i> = 1), ovine (<i>n</i> = 1), bovine (<i>n</i> = 1), and 3D-printed or molded aortic phantoms (<i>n</i> = 55). MCLs were employed to study parameters such as aortic stiffness, flow dynamics, dissection propagation, endoleaks, imaging accuracy, and device performance. <b>Conclusions</b>: This review provides a comprehensive overview of MCL applications in aortic research. MCLs represent a versatile pre-clinical platform for studying aortic pathophysiology and testing endovascular therapies under controlled conditions. Standardized reporting frameworks are now required to improve reproducibility and accelerate translation to patient-specific planning.

Authors

Institutions

Publication Details

Journal
Biomedicines
Published
2025-12-22
DOI
https://doi.org/10.3390/biomedicines14010028
Primary Topic
Coronary Interventions and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Current State of Mock Circulatory Loop Applications in Aortic and Cardiovascular Research: A Scoping Review

Nesar A Hasami, Martina Schembri, Ferdinando Auricchio, Jorg de Bruin et al.
Biomedicines
Coronary Interventions and Diagnostics
article

The Current State of Mock Circulatory Loop Applications in Aortic and Cardiovascular Research: A Scoping Review

Nesar A Hasami, Martina Schembri, Ferdinando Auricchio, Jorg de Bruin, Michele Conti, Alessandro Caimi, M. Domanin, Jasper F de Kort, Emma-Lena Maris, Constantijn E. V. B. Hazenberg, Felix E. N. Osinga, Santi Trimarchi, Joost A. van Herwaarden
article en

Abstract

<b>Background</b>: Mock circulatory loops (MCLs) are benchtop experimental platforms that reproduce key features of the human cardiovascular system, providing a safe, controlled, and reproducible environment for haemodynamic investigation. This scoping review aims to systematically map the current landscape of MCLs used for aortic simulation and identify major areas of application. <b>Methods</b>: A systematic search of PubMed, Scopus, and Web of Science identified original studies employing MCLs for aortic simulation. Eligible studies were categorized into predefined themes: (I) (bio)mechanical aortic characterization, (II) hemodynamics, (III) device testing, (IV) diagnostics, and (V) training. Data on MCL configurations, aortic models, and study objectives were synthesized narratively. <b>Results</b>: Eighty-four studies met the inclusion criteria. Twenty-five investigated aortic biomechanics, 23 hemodynamics, 22 device or product testing, 13 validated diagnostic imaging techniques, and one training application. Models included porcine (<i>n</i> = 22), human cadaveric (<i>n</i> = 7), canine (<i>n</i> = 1), ovine (<i>n</i> = 1), bovine (<i>n</i> = 1), and 3D-printed or molded aortic phantoms (<i>n</i> = 55). MCLs were employed to study parameters such as aortic stiffness, flow dynamics, dissection propagation, endoleaks, imaging accuracy, and device performance. <b>Conclusions</b>: This review provides a comprehensive overview of MCL applications in aortic research. MCLs represent a versatile pre-clinical platform for studying aortic pathophysiology and testing endovascular therapies under controlled conditions. Standardized reporting frameworks are now required to improve reproducibility and accelerate translation to patient-specific planning.

BiomedicinesVol. 14(1)
Radboud University Nijmegen (NL), University of Milan (IT), University of Pavia (IT), Erasmus MC (NL), Radboud University Medical Center (NL), Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico (IT), University Medical Center Utrecht (NL), IRCCS Policlinico San Donato (IT), Erasmus University Rotterdam (NL)
Openalex Percentile: Top 28%
Coronary Interventions and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.