Comparative analysis of cardiac function before LVAD implantation in patients with and without early, acute right heart failure

\(\bf Background:\) Early acute right heart failure (eaRHF) during left ventricular assist device (LVAD) implantation significantly impacts patient survival and complicates perioperative management. Although numerous clinical, echocardiographic, and hemodynamic risk factors have been identified, accurately predicting eaRHF remains challenging. Cardiac magnetic resonance (CMR) provides a precise, non-invasive evaluation of cardiac structure and function and may enhance risk stratification eaRHF. This study aims to assess the predictive value of preoperative CMR-derived parameters, comparing their utility to established echocardiographic and right heart catheterization (RHC) markers for identifying eaRHF. \(\bf Methods:\) This retrospective analysis was conducted on 55 patients who received CMR before LVAD implantation at our center between 2018 and 2024. Of these 55 patients, 40 had image quality sufficient for offline analysis. Patients receiving a temporary right ventricular assist device (tRVAD) intraoperatively were defined as having eaRHF. Receiver Operating Characteristic (ROC) analysis was used to evaluate the predictive capability of CMR, echocardiographic, and RHC parameters. \(\bf Results:\) Ten patients (25%) developed eaRHF. Preoperative bilirubin levels were significantly higher in the eaRHF group (1.6 mg/dl vs. 1.1 mg/dl, \(\it p\) = 0.010). Echocardiographic Tricuspid Annular Plane Systolic Excursion (TAPSE) tended to be lower in eaRHF patients (12 mm vs. 18 mm, \(\it p\) = 0.080). RHC parameters, specifically right ventricular stroke work index (RV-SWI; \(\it p\) < 0.001), cardiac output (CO; \(\it p\) = 0.003), and cardiac index (CI; \(\it p\) = 0.004), were significantly lower in eaRHF patients. CMR showed significantly higher RV end-diastolic volumes (RV-EDV, 288.4 ml vs. 216.7 ml, \(\it p\) = 0.046) and indexed RV-EDV (RV-EDVi, 135.4 ml/m\(^{2}\) vs. 104.7 ml/m\(^{2}\), \(\it p\) = 0.033) in the eaRHF group. ROC analysis identified CO (AUC = 0.90, sensitivity = 100%, specificity = 72%, \(\it p\) < 0.001), CI (AUC = 0.88, sensitivity = 83%, specificity = 83%, \(\it p\) < 0.001), and RV-SWI (AUC = 0.86, sensitivity = 83%, specificity = 86%, \(\it p\) < 0.001) as strong predictors. Moderate predictive values were observed for RV-EDVi (AUC = 0.73, \(\it p\) = 0.040) and RV global radial strain (RV-GRS; AUC = 0.70, \(\it p\) = 0.044). \(\bf Conclusion:\) Hemodynamic parameters from RHC demonstrated the strongest predictive capability for eaRHF. However, selected CMR-derived parameters, especially indexed RV-EDV and RV GRS, offer moderate predictive value and may serve as adjunctive tools in preoperative risk stratification for LVAD candidates.

Authors

Publication Details

Journal
Dokumentenrepositorium der RUB (Ruhr University Bochum)
Published
2025-09-24
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative analysis of cardiac function before LVAD implantation in patients with and without early, acute right heart failure

Jan Fritz Gummert, Lech Paluszkiewicz, Nikolai Hulde, Michiel Morshuis et al.
Dokumentenrepositorium der RUB (Ruhr University Bochum)
Mechanical Circulatory Support Devices
article

Comparative analysis of cardiac function before LVAD implantation in patients with and without early, acute right heart failure

Jan Fritz Gummert, Lech Paluszkiewicz, Nikolai Hulde, Michiel Morshuis, Hermann Körperich, C. Braun, S. Günther, Henrik (Prof. Dr. med.) Fox, Sebastian (PD Dr. med.) Rojas Hernandez
article en

Abstract

\(\bf Background:\) Early acute right heart failure (eaRHF) during left ventricular assist device (LVAD) implantation significantly impacts patient survival and complicates perioperative management. Although numerous clinical, echocardiographic, and hemodynamic risk factors have been identified, accurately predicting eaRHF remains challenging. Cardiac magnetic resonance (CMR) provides a precise, non-invasive evaluation of cardiac structure and function and may enhance risk stratification eaRHF. This study aims to assess the predictive value of preoperative CMR-derived parameters, comparing their utility to established echocardiographic and right heart catheterization (RHC) markers for identifying eaRHF. \(\bf Methods:\) This retrospective analysis was conducted on 55 patients who received CMR before LVAD implantation at our center between 2018 and 2024. Of these 55 patients, 40 had image quality sufficient for offline analysis. Patients receiving a temporary right ventricular assist device (tRVAD) intraoperatively were defined as having eaRHF. Receiver Operating Characteristic (ROC) analysis was used to evaluate the predictive capability of CMR, echocardiographic, and RHC parameters. \(\bf Results:\) Ten patients (25%) developed eaRHF. Preoperative bilirubin levels were significantly higher in the eaRHF group (1.6 mg/dl vs. 1.1 mg/dl, \(\it p\) = 0.010). Echocardiographic Tricuspid Annular Plane Systolic Excursion (TAPSE) tended to be lower in eaRHF patients (12 mm vs. 18 mm, \(\it p\) = 0.080). RHC parameters, specifically right ventricular stroke work index (RV-SWI; \(\it p\) < 0.001), cardiac output (CO; \(\it p\) = 0.003), and cardiac index (CI; \(\it p\) = 0.004), were significantly lower in eaRHF patients. CMR showed significantly higher RV end-diastolic volumes (RV-EDV, 288.4 ml vs. 216.7 ml, \(\it p\) = 0.046) and indexed RV-EDV (RV-EDVi, 135.4 ml/m\(^{2}\) vs. 104.7 ml/m\(^{2}\), \(\it p\) = 0.033) in the eaRHF group. ROC analysis identified CO (AUC = 0.90, sensitivity = 100%, specificity = 72%, \(\it p\) < 0.001), CI (AUC = 0.88, sensitivity = 83%, specificity = 83%, \(\it p\) < 0.001), and RV-SWI (AUC = 0.86, sensitivity = 83%, specificity = 86%, \(\it p\) < 0.001) as strong predictors. Moderate predictive values were observed for RV-EDVi (AUC = 0.73, \(\it p\) = 0.040) and RV global radial strain (RV-GRS; AUC = 0.70, \(\it p\) = 0.044). \(\bf Conclusion:\) Hemodynamic parameters from RHC demonstrated the strongest predictive capability for eaRHF. However, selected CMR-derived parameters, especially indexed RV-EDV and RV GRS, offer moderate predictive value and may serve as adjunctive tools in preoperative risk stratification for LVAD candidates.

Dokumentenrepositorium der RUB (Ruhr University Bochum)
Good health and well-being
Openalex Percentile: Top 43%
Mechanical Circulatory Support Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.