A new hybrid approach for automated leakage detection in fundus fluorescein angiography images

The existing methods for quantitative investigation of leakage in fluorescein angiography (FA) images involve manual delineation and lack annotated datasets and high accuracy. The proposed hybrid approach can automatically detect leakage in FA images with high accuracy. The hybrid approach combines the fuzzy c-means (FCM) with distance regularised level set evolution (DRLSE). Two expert radiologists test the accuracy of the proposed system. We have also tested inter-and intra-observer variability between the two experts. The study observed high accuracy of 0.98 ± 0.02 and 0.98 ± 0.03 with experts 1 and 2, respectively. Further, the accuracy of manual inter-observer (expert 1 and expert 2) and intra-observer (expert 1) were observed as 0.95 ± 0.05 and 0.98 ± 0.02, respectively. The proposed fully automated hybrid approach can accurately detect and quantify the leakage in FA images and thus has great potential value in diabetic retinopathy (DR).

Authors

Institutions

Publication Details

Journal
International Journal of Medical Engineering and Informatics
Published
2025-12-20
DOI
https://doi.org/10.1504/ijmei.2026.150647
Primary Topic
Retinal Imaging and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A new hybrid approach for automated leakage detection in fundus fluorescein angiography images

Ravi Khatri, Deepak Chandravanshi, Suraj Chandrakar, Bikesh Kumar Singh et al.
International Journal of Medical Engineering and Informatics
Retinal Imaging and Analysis
article

A new hybrid approach for automated leakage detection in fundus fluorescein angiography images

Ravi Khatri, Deepak Chandravanshi, Suraj Chandrakar, Bikesh Kumar Singh, Ankur Khare, Sumit Kumar Banchhor
article en

Abstract

The existing methods for quantitative investigation of leakage in fluorescein angiography (FA) images involve manual delineation and lack annotated datasets and high accuracy. The proposed hybrid approach can automatically detect leakage in FA images with high accuracy. The hybrid approach combines the fuzzy c-means (FCM) with distance regularised level set evolution (DRLSE). Two expert radiologists test the accuracy of the proposed system. We have also tested inter-and intra-observer variability between the two experts. The study observed high accuracy of 0.98 ± 0.02 and 0.98 ± 0.03 with experts 1 and 2, respectively. Further, the accuracy of manual inter-observer (expert 1 and expert 2) and intra-observer (expert 1) were observed as 0.95 ± 0.05 and 0.98 ± 0.02, respectively. The proposed fully automated hybrid approach can accurately detect and quantify the leakage in FA images and thus has great potential value in diabetic retinopathy (DR).

International Journal of Medical Engineering and InformaticsVol. 18(1)
National Institute of Technology Raipur (IN)
Openalex Percentile: Top 32%
Retinal Imaging and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A new hybrid approach for automated leakage detection in fundus fluorescein angiography images — Ravi Khatri, Deepak Chandravanshi, et al. · International Journal of Medical Engineering and Informatics (2025) | TGRS Research Map | TGRS