Optimized ultrasound imaging of phase-change nanodroplets

Phase-change nanodroplets (PCNDs) continue to generate significant research interest due to their potential to extravasate into tissue, to be targeted for molecular imaging and drug delivery, and to undergo an induced phase-change to "activated" microbubbles (MBs) for ultrasound (US) imaging. To accurately quantify molecular markers, however, one assumes a consistent proportion of PCNDs in a region of interest (ROI) are stably activated and imaged. Herein we present a framework for developing a diagnostic sequence that is optimized for PCND activation uniformity, contrast, and acquisition time. To develop this framework, activation was examined at three scales of increasing complexity: single, adjacent, and full ROI activation(s). First, transmit parameters for a single activation were optimized using PCNDs across concentrations (1.0 × 10<sup>7</sup>-10<sup>9</sup> PCND/mL) in controlled phantom experiments, considering contrast-to-noise ratio (CNR), area, and offset (e.g., centroid axial distance from transmit focus) of the activation region along with acquisition time. Activation regions were also compared to prospective estimates based on US-beam imaging. Next, overlap and order of adjacent activation regions was optimized by maximizing spacing while preserving uniformity and minimizing signal loss from adjacent transmit interactions. Finally, an optimized raster-scanning scheme was applied to a mock tumor ROI, yielding 1.4-7.0 dB greater contrast enhancement over unoptimized schemes while reducing acquisition time. Further, PCND concentration was found to share a nonlinear relationship with US signal enhancement that differed significantly between linear and harmonic imaging modes. In conclusion, our framework's optimization of contrast, uniformity, acquisition time, and cavitation mitigation for PCND US imaging should help facilitate its eventual clinical translation.

Authors

Institutions

Publication Details

Journal
Ultrasonics
Published
2025-12-20
DOI
https://doi.org/10.1016/j.ultras.2025.107933
Primary Topic
Ultrasound and Hyperthermia Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimized ultrasound imaging of phase-change nanodroplets

Konstantin Sokolov, Trevor Mitcham, Richard R. Bouchard, George J. Lu et al.
Ultrasonics
Ultrasound and Hyperthermia Applications
article

Optimized ultrasound imaging of phase-change nanodroplets

Konstantin Sokolov, Trevor Mitcham, Richard R. Bouchard, George J. Lu, Dmitry Nevozhay, Charles Raymond Dyall, Andy Liu
article en

Abstract

Phase-change nanodroplets (PCNDs) continue to generate significant research interest due to their potential to extravasate into tissue, to be targeted for molecular imaging and drug delivery, and to undergo an induced phase-change to "activated" microbubbles (MBs) for ultrasound (US) imaging. To accurately quantify molecular markers, however, one assumes a consistent proportion of PCNDs in a region of interest (ROI) are stably activated and imaged. Herein we present a framework for developing a diagnostic sequence that is optimized for PCND activation uniformity, contrast, and acquisition time. To develop this framework, activation was examined at three scales of increasing complexity: single, adjacent, and full ROI activation(s). First, transmit parameters for a single activation were optimized using PCNDs across concentrations (1.0 × 10<sup>7</sup>-10<sup>9</sup> PCND/mL) in controlled phantom experiments, considering contrast-to-noise ratio (CNR), area, and offset (e.g., centroid axial distance from transmit focus) of the activation region along with acquisition time. Activation regions were also compared to prospective estimates based on US-beam imaging. Next, overlap and order of adjacent activation regions was optimized by maximizing spacing while preserving uniformity and minimizing signal loss from adjacent transmit interactions. Finally, an optimized raster-scanning scheme was applied to a mock tumor ROI, yielding 1.4-7.0 dB greater contrast enhancement over unoptimized schemes while reducing acquisition time. Further, PCND concentration was found to share a nonlinear relationship with US signal enhancement that differed significantly between linear and harmonic imaging modes. In conclusion, our framework's optimization of contrast, uniformity, acquisition time, and cavitation mitigation for PCND US imaging should help facilitate its eventual clinical translation.

UltrasonicsVol. 161
The University of Texas MD Anderson Cancer Center (US), University of Rochester Medical Center (US), University of Rochester (US), Rice University (US)
Hearing Health Foundation, Cancer Prevention and Research Institute of Texas, John S. Dunn Foundation, Rice University, National Institutes of Health
Partnerships for the goals
Openalex Percentile: Top 43%
Ultrasound and Hyperthermia Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.