Effects of various phases and errors on partial volume estimation in the analysis of PV correction in ASL MRI

Arterial spin labelling (ASL) MRI is widely used to measure cerebral blood flow (CBF). The low resolution of ASL images causes partial volume (PV) effect that causes an erroneous estimation of CBF values. A two-phase study is conducted to investigate the impact of various factors on the PV correction technique using linear regression. The effects of different stages in the PV estimation process are examined in the first phase, and the impact of noise and blurring on PV estimates on the second phase. Experiments are conducted on simulated PCASL images generated from ADNI and the results are validated using RMSE score and ROI analysis.

Authors

Institutions

Publication Details

Journal
International Journal of Medical Engineering and Informatics
Published
2025-12-20
DOI
https://doi.org/10.1504/ijmei.2026.150645
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effects of various phases and errors on partial volume estimation in the analysis of PV correction in ASL MRI

Amma C. Ushadevi, Bright Thomas, Ansamma John, C. Kesavadas et al.
International Journal of Medical Engineering and Informatics
Advanced MRI Techniques and Applications
article

Effects of various phases and errors on partial volume estimation in the analysis of PV correction in ASL MRI

Amma C. Ushadevi, Bright Thomas, Ansamma John, C. Kesavadas, A. Shyna
article en

Abstract

Arterial spin labelling (ASL) MRI is widely used to measure cerebral blood flow (CBF). The low resolution of ASL images causes partial volume (PV) effect that causes an erroneous estimation of CBF values. A two-phase study is conducted to investigate the impact of various factors on the PV correction technique using linear regression. The effects of different stages in the PV estimation process are examined in the first phase, and the impact of noise and blurring on PV estimates on the second phase. Experiments are conducted on simulated PCASL images generated from ADNI and the results are validated using RMSE score and ROI analysis.

International Journal of Medical Engineering and InformaticsVol. 18(1)
Sree Chitra Thirunal Institute for Medical Sciences and Technology (IN), APJ Abdul Kalam Technological University (IN), Institute of Medical Sciences (IN), Amrita Vishwa Vidyapeetham (IN)
Openalex Percentile: Top 32%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.