Trypsin digestion to prevent acid induced precipitation of metalloproteins for accurate ICP-MS analysis: Nitrogenase case study

Accurate determination of metallation states in metalloenzymes is essential for correlating metal content with enzymatic function. Inductively coupled plasma mass spectrometry (ICP-MS) and optical emission spectroscopy (ICP-OES) are among the most sensitive and practical techniques for this purpose. However, complete digestion of protein samples is critical for accurate results, and the use of acid often leads to protein precipitation before the metals are fully released into solution. Here, we present a case study using the nitrogenase protein NifDK, which contains both Fe and Mo, to demonstrate that trypsin digestion can prevent acid-induced precipitation. A 1:1 (w/w) ratio of protein to trypsin in Tris buffer at 37 °C overnight results in complete digestion of NifDK. Upon acid addition, a homogeneous solution is obtained without precipitation. This approach yields highly reproducible ICP-MS data. Further improvements include performing protein quantification on the exact vial used for ICP-MS analysis, applying a drift correction to the ICP-MS data, and using nitric acid with 0.1 % (v/v) HF for accurate molybdenum quantification.

Authors

Institutions

Publication Details

Journal
Analytical Biochemistry
Published
2025-12-20
DOI
https://doi.org/10.1016/j.ab.2025.116035
Primary Topic
Metalloenzymes and iron-sulfur proteins
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Trypsin digestion to prevent acid induced precipitation of metalloproteins for accurate ICP-MS analysis: Nitrogenase case study

Christina M. Gregg, Trevor D. Rapson, Jessica K. Bilyj
Analytical Biochemistry
Metalloenzymes and iron-sulfur proteins
article

Trypsin digestion to prevent acid induced precipitation of metalloproteins for accurate ICP-MS analysis: Nitrogenase case study

Christina M. Gregg, Trevor D. Rapson, Jessica K. Bilyj
article en

Abstract

Accurate determination of metallation states in metalloenzymes is essential for correlating metal content with enzymatic function. Inductively coupled plasma mass spectrometry (ICP-MS) and optical emission spectroscopy (ICP-OES) are among the most sensitive and practical techniques for this purpose. However, complete digestion of protein samples is critical for accurate results, and the use of acid often leads to protein precipitation before the metals are fully released into solution. Here, we present a case study using the nitrogenase protein NifDK, which contains both Fe and Mo, to demonstrate that trypsin digestion can prevent acid-induced precipitation. A 1:1 (w/w) ratio of protein to trypsin in Tris buffer at 37 °C overnight results in complete digestion of NifDK. Upon acid addition, a homogeneous solution is obtained without precipitation. This approach yields highly reproducible ICP-MS data. Further improvements include performing protein quantification on the exact vial used for ICP-MS analysis, applying a drift correction to the ICP-MS data, and using nitric acid with 0.1 % (v/v) HF for accurate molybdenum quantification.

Analytical BiochemistryVol. 710
Commonwealth Scientific and Industrial Research Organisation (AU)
Clean water and sanitation
Openalex Percentile: Top 53%
Metalloenzymes and iron-sulfur proteins
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.