To Compare and Evaluate The Effect of Commercially Available Denture Cleansers on the Color Stability, Flexural Strength and Surface Roughness of Two Different Types of Denture Base Materials -An in-Vitro Study

Abstract Aim: The Purpose of this in Vitro Study was to compare and evaluate the effect of commercially available denture cleansers on the color stability, flexural strength and surface roughness of two different types of denture base materials. Materials and Methods: In order to conduct this study a metal mould with specific dimensions were fabricated to make the heat cure acrylic and polyamide Lucitone denture base specimens. A total of 160 samples were included in the study which were divided on the basis of denture base materials into two groups: Group 1 Heat cure acrylic denture base resin and Group 2: Polyamide resin- Lucitone denture base resin. Group 1 and Group 2 were further divided into 4 subgroups based on the different denture cleansers. Sample of heat cure acrylic resin and polyamide resin –Lucitone of specific dimensions will be prepared using modelling wax and metal mould. Three types of commercially available denture cleansers will be prepared as per manufacturer’s instructions. After 90 days of immersion period, samples were subjected to spectrophotometer for color stability test, Surface roughness tester and universal testing machine under 3-point loading to check for the flexural strength of the specimens. The data collected will be subjected to statistical analysis. Results: To compare the data of these groups, it was preferred to apply one way ANOVA and POST HOC TEST for testing the difference of mean in between the groups. The level of significance was set at P- value < 0.05. Among all the three denture cleansers used in our study group1{acrylic resin} showed statistically minimal reduction in values of flexural strength with Fittydent in comparison to Secure and Clinsodent. Similarly group2 {Lucitone- polyamide resin} showed statistically minimal reduction in values of flexural strength with Fittydent in comparison to Secure and Clinsodent. On immersion of specimens of both the groups in Clinsodent, Fittydent, and Secure denture cleansers, reduced flexural strength of the heat-cured acrylic resin and Lucitone- polyamide resin was observed in comparison to distilled water. In this study acrylic resin group exhibited change in surface roughness which was seen maximum with Clinsodent. Surface roughness of acrylic resin with Clinsodent and Secure was camparable. Fittydent showed least change in surface roughness in camparison with control group. Similar result pattern was observed in lucitone- polyamide group. ANNOVA and POST HOC TEST showed the result to be satisficing when three commercially available denture cleanser were taken into consideration.

Authors

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-09-30
DOI
https://doi.org/10.5281/zenodo.17986481
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

To Compare and Evaluate The Effect of Commercially Available Denture Cleansers on the Color Stability, Flexural Strength and Surface Roughness of Two Different Types of Denture Base Materials -An in-Vitro Study

International Journal of Dental Science and Innovative Research (IJDSIR)
Zenodo (CERN European Organization for Nuclear Research)
Dental materials and restorations
article

To Compare and Evaluate The Effect of Commercially Available Denture Cleansers on the Color Stability, Flexural Strength and Surface Roughness of Two Different Types of Denture Base Materials -An in-Vitro Study

International Journal of Dental Science and Innovative Research (IJDSIR)
article en

Abstract

Abstract Aim: The Purpose of this in Vitro Study was to compare and evaluate the effect of commercially available denture cleansers on the color stability, flexural strength and surface roughness of two different types of denture base materials. Materials and Methods: In order to conduct this study a metal mould with specific dimensions were fabricated to make the heat cure acrylic and polyamide Lucitone denture base specimens. A total of 160 samples were included in the study which were divided on the basis of denture base materials into two groups: Group 1 Heat cure acrylic denture base resin and Group 2: Polyamide resin- Lucitone denture base resin. Group 1 and Group 2 were further divided into 4 subgroups based on the different denture cleansers. Sample of heat cure acrylic resin and polyamide resin –Lucitone of specific dimensions will be prepared using modelling wax and metal mould. Three types of commercially available denture cleansers will be prepared as per manufacturer’s instructions. After 90 days of immersion period, samples were subjected to spectrophotometer for color stability test, Surface roughness tester and universal testing machine under 3-point loading to check for the flexural strength of the specimens. The data collected will be subjected to statistical analysis. Results: To compare the data of these groups, it was preferred to apply one way ANOVA and POST HOC TEST for testing the difference of mean in between the groups. The level of significance was set at P- value < 0.05. Among all the three denture cleansers used in our study group1{acrylic resin} showed statistically minimal reduction in values of flexural strength with Fittydent in comparison to Secure and Clinsodent. Similarly group2 {Lucitone- polyamide resin} showed statistically minimal reduction in values of flexural strength with Fittydent in comparison to Secure and Clinsodent. On immersion of specimens of both the groups in Clinsodent, Fittydent, and Secure denture cleansers, reduced flexural strength of the heat-cured acrylic resin and Lucitone- polyamide resin was observed in comparison to distilled water. In this study acrylic resin group exhibited change in surface roughness which was seen maximum with Clinsodent. Surface roughness of acrylic resin with Clinsodent and Secure was camparable. Fittydent showed least change in surface roughness in camparison with control group. Similar result pattern was observed in lucitone- polyamide group. ANNOVA and POST HOC TEST showed the result to be satisficing when three commercially available denture cleanser were taken into consideration.

Zenodo (CERN European Organization for Nuclear Research)
International Association for Dental Research (US)
Openalex Percentile: Top 35%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.