Comparative image quality evaluation of unenhanced postmortem Photon-Counting CT and Energy-Integrating CT.

This study evaluates the image quality of postmortem photon-counting computed tomography (PMPCCT) compared to conventional postmortem energy-integrating computed tomography (PMCT) for a protocol adapted to post-mortem imaging. The focus lies on objective image quality parameters such as noise, signal-to-noise ratio, and contrast-to-noise ratio, supplemented by subjective image quality evaluations. A Chest Phantom N1 and one decedent were scanned using PMCT (Siemens SOMATOM® X-Cite; slice thicknesses of 1 mm and 0.5 mm; Br40, Br60) and PMPCCT (Siemens NAEOTOM Alpha.peak®; slice thicknesses of 1 mm, 0.4 mm, and 0.2 mm; Br40, Br60). Image quality parameters were computed for regions of interest. In addition, two radiologists conducted subjective image quality evaluations (noise, overall image quality, sharpness, bone details, contour visibility, and artifact formation) using a modified Likert scale. The overall findings were mixed, with PMPCCT potentially demonstrating an advantage over PMCT in terms of SNR and CNR, particularly at moderate slice thicknesses of 1 mm and 0.4 mm. The results obtained from the phantom exhibit in some cases considerable differences compared to those from the decedent, so that model studies can hardly be transferred to reality without scrutiny. PMPCCT outperformed PMCT in subjective assessments of overall image quality, sharpness, and bone detail, particularly with Br40 reconstruction kernels. PMPCCT may demonstrate advantages in objective and subjective image quality, with improvements in soft tissue imaging, sharpness, and bone detail at moderate slice thicknesses. These results may suggest PMPCCTs promising potential in forensic imaging. Further studies are needed to investigate and optimize its utility in postmortem settings.

Authors

Institutions

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2025-12-06
DOI
https://doi.org/10.48620/93235
Primary Topic
Autopsy Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative image quality evaluation of unenhanced postmortem Photon-Counting CT and Energy-Integrating CT.

Peter H. Cossmann, S. Garni, Paolo Lombardo, Wolf-Dieter Zech et al.
Open Access CRIS of the University of Bern
Autopsy Techniques and Outcomes
article

Comparative image quality evaluation of unenhanced postmortem Photon-Counting CT and Energy-Integrating CT.

Peter H. Cossmann, S. Garni, Paolo Lombardo, Wolf-Dieter Zech, Magda Roidou, Thomas Ruder, Conny Hartmann, Sarah Heinze, Hendrik von Tengg-Kobligk, Samira Kessler
article en

Abstract

This study evaluates the image quality of postmortem photon-counting computed tomography (PMPCCT) compared to conventional postmortem energy-integrating computed tomography (PMCT) for a protocol adapted to post-mortem imaging. The focus lies on objective image quality parameters such as noise, signal-to-noise ratio, and contrast-to-noise ratio, supplemented by subjective image quality evaluations. A Chest Phantom N1 and one decedent were scanned using PMCT (Siemens SOMATOM® X-Cite; slice thicknesses of 1 mm and 0.5 mm; Br40, Br60) and PMPCCT (Siemens NAEOTOM Alpha.peak®; slice thicknesses of 1 mm, 0.4 mm, and 0.2 mm; Br40, Br60). Image quality parameters were computed for regions of interest. In addition, two radiologists conducted subjective image quality evaluations (noise, overall image quality, sharpness, bone details, contour visibility, and artifact formation) using a modified Likert scale. The overall findings were mixed, with PMPCCT potentially demonstrating an advantage over PMCT in terms of SNR and CNR, particularly at moderate slice thicknesses of 1 mm and 0.4 mm. The results obtained from the phantom exhibit in some cases considerable differences compared to those from the decedent, so that model studies can hardly be transferred to reality without scrutiny. PMPCCT outperformed PMCT in subjective assessments of overall image quality, sharpness, and bone detail, particularly with Br40 reconstruction kernels. PMPCCT may demonstrate advantages in objective and subjective image quality, with improvements in soft tissue imaging, sharpness, and bone detail at moderate slice thicknesses. These results may suggest PMPCCTs promising potential in forensic imaging. Further studies are needed to investigate and optimize its utility in postmortem settings.

Open Access CRIS of the University of Bern
Society of Interventional Radiology (US), Institute of Forensic Science (CN)
Affordable and clean energy
Openalex Percentile: Top 32%
Autopsy Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.