Separation and quantification of novel synthetic regioisomeric fentanyls in clinical extracts by high pH reverse-phase LC-MS/MS

This study compares three different chromatographic methods used for the separation of regioisomeric fluorofentanyl, as described in previous literature, through application to clinical whole blood extracts. A high pH, RP-UHPLC-MS/MS method was selected and a series of opioids ( n = 23), including regioisomeric series of fluorofentanyl, despropionylfluorofentanyl, and fluoroisobutyrylfentanyl ( n = 13), fentanyl and other fentanyl analogues ( n = 8), heroin and xylazine, were successfully validated against UKAS LAB51 and SWGTOX guidelines using this method. The results of the validation demonstrated R 2 greater than 0.99 for all analytes except heroin ( n = 22), accuracy ranging from 96.8 % to 110.1 % and precision between 0.8 % to 13.2 % as percentage coefficient of variation across replicate injections ( n = 9) of three different quality control levels for all analytes except heroin (n = 22). Limits of detection ranged from 0.016 ng/mL to 0.24 ng/mL and limits of quantification ranged from 0.049 ng/mL to 0.729 ng/mL. Clinical whole blood extracts were screened by high-resolution mass spectrometry and triaged for further identification and quantification of regioisomeric compounds where an unknown regioisomeric form of fluorofentanyl was found. Across all sample extracts para -fluorofentanyl was successfully identified, alongside potential interferences including other drugs of abuse (cocaine, methamphetamine, gabapentin) and cutting agents (procaine, lidocaine), and quantified within the range of 0.44 ng/mL to 31.16 ng/mL, with fentanyl, para -despropionylfluorofentanyl, and 4-ANPP detected and quantified in all samples with para -fluorofentanyl. • Comparison of chromatography for quantifying regioisomeric fluorofentanyls. • Partial method validation complying with SWGTOX guidelines. • Screening of extracts by high-resolution mass spectrometry for fluorofentanyl. • Quantification of previously unidentified fluorofentanyl.

Institutions

Publication Details

Journal
Forensic Chemistry
Published
2025-12-19
DOI
https://doi.org/10.1016/j.forc.2025.100721
Citations
1
Primary Topic
Forensic Toxicology and Drug Analysis
Type
article
Field-Weighted Citation Impact
1.31
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Separation and quantification of novel synthetic regioisomeric fentanyls in clinical extracts by high pH reverse-phase LC-MS/MS

1 citations
Forensic Chemistry
Forensic Toxicology and Drug Analysis
1.31
article

Separation and quantification of novel synthetic regioisomeric fentanyls in clinical extracts by high pH reverse-phase LC-MS/MS

article en
1 citations

Abstract

This study compares three different chromatographic methods used for the separation of regioisomeric fluorofentanyl, as described in previous literature, through application to clinical whole blood extracts. A high pH, RP-UHPLC-MS/MS method was selected and a series of opioids ( n = 23), including regioisomeric series of fluorofentanyl, despropionylfluorofentanyl, and fluoroisobutyrylfentanyl ( n = 13), fentanyl and other fentanyl analogues ( n = 8), heroin and xylazine, were successfully validated against UKAS LAB51 and SWGTOX guidelines using this method. The results of the validation demonstrated R 2 greater than 0.99 for all analytes except heroin ( n = 22), accuracy ranging from 96.8 % to 110.1 % and precision between 0.8 % to 13.2 % as percentage coefficient of variation across replicate injections ( n = 9) of three different quality control levels for all analytes except heroin (n = 22). Limits of detection ranged from 0.016 ng/mL to 0.24 ng/mL and limits of quantification ranged from 0.049 ng/mL to 0.729 ng/mL. Clinical whole blood extracts were screened by high-resolution mass spectrometry and triaged for further identification and quantification of regioisomeric compounds where an unknown regioisomeric form of fluorofentanyl was found. Across all sample extracts para -fluorofentanyl was successfully identified, alongside potential interferences including other drugs of abuse (cocaine, methamphetamine, gabapentin) and cutting agents (procaine, lidocaine), and quantified within the range of 0.44 ng/mL to 31.16 ng/mL, with fentanyl, para -despropionylfluorofentanyl, and 4-ANPP detected and quantified in all samples with para -fluorofentanyl. • Comparison of chromatography for quantifying regioisomeric fluorofentanyls. • Partial method validation complying with SWGTOX guidelines. • Screening of extracts by high-resolution mass spectrometry for fluorofentanyl. • Quantification of previously unidentified fluorofentanyl.

Forensic ChemistryVol. 47
Manchester Metropolitan University (GB), Pennsylvania State University (US), University of Strathclyde (GB), The Open University (GB), Kingston University London (GB), Milton Keynes Hospital (GB)
Good health and well-being
Openalex Percentile: Top 16%
Forensic Toxicology and Drug Analysis
1.31
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.