Determination of insensible water loss and sodium accumulation behavior from the Medtronic Nautilus Extracorporeal Membrane Oxygenation (ECMO) oxygenator: An in vitro study

Introduction: Fluid and electrolyte balance is closely managed in extracorporeal membrane oxygenation (ECMO) patients. Neglecting oxygenator-related insensible fluid losses can distort fluid balance and electrolyte levels. While ECMO oxygenator insensible losses are reported, they remain undefined for the Medtronic Nautilus oxygenator. Through in vitro analysis of the Nautilus, we quantified insensible water losses while concurrently observing sodium behavior. Methods: Insensible water losses were determined using a closed circuit. A 12-hour pilot run was conducted to saturate the oxygenator and determine probable water loss rates and sodium accumulation behaviors. Fluid loss and sodium measurements were made at 0, 6, and 12 h. Immediately following the pilot run, three randomly assigned sweep gas rates, 0.5, 1.0, and 1.5 L/min, were evaluated over a 24 h period and replicated in triplicate. The circuit parameters were consistent and controlled for each trial. Data were collected at 0, 12, and 24 h for visualized water loss in the reservoir. After each trial, sterile water was introduced into the circuit via syringe and recorded as replacement volume. Sodium measurements were made for three trials (0.5, 1.0, and 1.5) and collected at 0 and 24 h. Results: Using linear regression analysis, the following insensible water loss equations were produced. Visualized volume: 2.74 mL/h per 1 L/min sweep gas rate or 65.66 mL/day per 1 L/min of sweep gas rate (p < 0.001). Replacement volume: 3.02 mL/h per 1 L/min of sweep gas rate or 72.5 mL/day per 1 L/min of sweep rate (p < 0.001). Sodium accumulation was observed, but not statistically significant due to the small sample size. Conclusion: Insensible water loss in the Nautilus ECMO oxygenator increases linearly with sweep gas rate (p < 0.001), leading to sodium accumulation through evaporation. These losses and the associated risk for hypernatremia should be considered when managing a patient’s fluid and electrolyte balance on ECMO.

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2025-12-17
DOI
https://doi.org/10.1051/ject/2025026/pdf
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determination of insensible water loss and sodium accumulation behavior from the Medtronic Nautilus Extracorporeal Membrane Oxygenation (ECMO) oxygenator: An in vitro study

Springer Link (Chiba Institute of Technology)
Mechanical Circulatory Support Devices
article

Determination of insensible water loss and sodium accumulation behavior from the Medtronic Nautilus Extracorporeal Membrane Oxygenation (ECMO) oxygenator: An in vitro study

article en

Abstract

Introduction: Fluid and electrolyte balance is closely managed in extracorporeal membrane oxygenation (ECMO) patients. Neglecting oxygenator-related insensible fluid losses can distort fluid balance and electrolyte levels. While ECMO oxygenator insensible losses are reported, they remain undefined for the Medtronic Nautilus oxygenator. Through in vitro analysis of the Nautilus, we quantified insensible water losses while concurrently observing sodium behavior. Methods: Insensible water losses were determined using a closed circuit. A 12-hour pilot run was conducted to saturate the oxygenator and determine probable water loss rates and sodium accumulation behaviors. Fluid loss and sodium measurements were made at 0, 6, and 12 h. Immediately following the pilot run, three randomly assigned sweep gas rates, 0.5, 1.0, and 1.5 L/min, were evaluated over a 24 h period and replicated in triplicate. The circuit parameters were consistent and controlled for each trial. Data were collected at 0, 12, and 24 h for visualized water loss in the reservoir. After each trial, sterile water was introduced into the circuit via syringe and recorded as replacement volume. Sodium measurements were made for three trials (0.5, 1.0, and 1.5) and collected at 0 and 24 h. Results: Using linear regression analysis, the following insensible water loss equations were produced. Visualized volume: 2.74 mL/h per 1 L/min sweep gas rate or 65.66 mL/day per 1 L/min of sweep gas rate (p < 0.001). Replacement volume: 3.02 mL/h per 1 L/min of sweep gas rate or 72.5 mL/day per 1 L/min of sweep rate (p < 0.001). Sodium accumulation was observed, but not statistically significant due to the small sample size. Conclusion: Insensible water loss in the Nautilus ECMO oxygenator increases linearly with sweep gas rate (p < 0.001), leading to sodium accumulation through evaporation. These losses and the associated risk for hypernatremia should be considered when managing a patient’s fluid and electrolyte balance on ECMO.

Springer Link (Chiba Institute of Technology)
Clean water and sanitation
Openalex Percentile: Top 44%
Mechanical Circulatory Support Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.