Biomechanical influence of femoral stem design on periprosthetic femoral fractures in dorr type C femurs with normal bone quality

Periprosthetic femoral fracture (PFF) is a major complication following total hip arthroplasty (THA), particularly in patients with Dorr type C femurs, which have normal bone quality. Implant selection plays a critical role in early postoperative stability, but the biomechanical influence of different femoral stem designs in this high-risk population remains unclear. In this study, CT data from a Dorr type C femur with normal bone quality, obtained from a patient with hip osteoarthritis, were used to reconstruct a three-dimensional femoral model. Six femoral stems representing different designs were implanted to construct corresponding THA finite element models. The models were subjected to a simulated stumbling condition, with progressively applied axial displacement until PFF occurred. The maximum fracture load was recorded and compared among the stem designs. The maximum fracture load, ranked from highest to lowest, was as follow: Corail (6079.26 N), Omnifit (5605.11 N), Synergy (5165.03 N), Taperloc (5030.77 N), Excia (4192.37 N), and Profemur (4034.64 N). The Excia and Profemur stems showing lower fracture loads than the peak stumbling load of approximately 8.7 times body weight (4785 N). These results suggest that, for THA in patients with Dorr type C femurs with normal bone quality, the use of Corail, Omnifit, Synergy, or Taperloc stems may be preferable for minimizing the risk of postoperative PFF. • Six femoral stem designs were compared in Dorr type C femurs with normal bone quality. • Corail and Omnifit stems exhibited superior resistance to periprosthetic femoral fracture. • Excia and Profemur stems fractured below the stumbling peak load threshold. • Stem geometry strongly determined fracture onset, pattern, and mechanical stability. • Results provide guidance for stem selection to reduce postoperative PFF risk in THA.

Institutions

Publication Details

Journal
Medicine in Novel Technology and Devices
Published
2025-12-19
DOI
https://doi.org/10.1016/j.medntd.2025.100423
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Biomechanical influence of femoral stem design on periprosthetic femoral fractures in dorr type C femurs with normal bone quality

Medicine in Novel Technology and Devices
Orthopaedic implants and arthroplasty
article

Biomechanical influence of femoral stem design on periprosthetic femoral fractures in dorr type C femurs with normal bone quality

article en

Abstract

Periprosthetic femoral fracture (PFF) is a major complication following total hip arthroplasty (THA), particularly in patients with Dorr type C femurs, which have normal bone quality. Implant selection plays a critical role in early postoperative stability, but the biomechanical influence of different femoral stem designs in this high-risk population remains unclear. In this study, CT data from a Dorr type C femur with normal bone quality, obtained from a patient with hip osteoarthritis, were used to reconstruct a three-dimensional femoral model. Six femoral stems representing different designs were implanted to construct corresponding THA finite element models. The models were subjected to a simulated stumbling condition, with progressively applied axial displacement until PFF occurred. The maximum fracture load was recorded and compared among the stem designs. The maximum fracture load, ranked from highest to lowest, was as follow: Corail (6079.26 N), Omnifit (5605.11 N), Synergy (5165.03 N), Taperloc (5030.77 N), Excia (4192.37 N), and Profemur (4034.64 N). The Excia and Profemur stems showing lower fracture loads than the peak stumbling load of approximately 8.7 times body weight (4785 N). These results suggest that, for THA in patients with Dorr type C femurs with normal bone quality, the use of Corail, Omnifit, Synergy, or Taperloc stems may be preferable for minimizing the risk of postoperative PFF. • Six femoral stem designs were compared in Dorr type C femurs with normal bone quality. • Corail and Omnifit stems exhibited superior resistance to periprosthetic femoral fracture. • Excia and Profemur stems fractured below the stumbling peak load threshold. • Stem geometry strongly determined fracture onset, pattern, and mechanical stability. • Results provide guidance for stem selection to reduce postoperative PFF risk in THA.

Medicine in Novel Technology and DevicesVol. 29
Shanghai Jiao Tong University (CN), Ningbo No. 2 Hospital (CN), Shanghai First People's Hospital (CN), The Second Affiliated Hospital of Bengbu Medical College (CN), Ningbo No.6 Hospital (CN), Beihang University (CN)
Openalex Percentile: Top 28%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.