Gestational age estimation using fetal transcerebellar diameter and choroid plexus length compared with conventional biometric parameters in healthy Nigerian women: A longitudinal study

ABSTRACT Background: The decline in the accuracy of biparietal diameter (BPD), head circumference (HC), femur length (FL), and abdominal circumference (AC) as gestation advances has complicated the distinction between pre- and postterm pregnancies. This study evaluated the correlation between the gestational age (GA) obtained from transcerebellar diameter (TCD) and choroid plexus length (CPL) with the GA obtained using crown-rump length (CRL) and compared the GA obtained from TCD and CPL with the average GA from the conventional biometric parameters. Methods: This longitudinal prospective study was conducted from December 2023 to May 2025 on 204 pregnant women between 14 and 40 weeks of gestation in a private hospital in Nigeria. A Mindray DC-7 ultrasound system, with a 3.5 MHz curvilinear probe, was used. TCD and CPL were measured using the suboccipitobregmatic and transventricular planes, respectively. Data were analyzed using paired sample t- tests, with statistical significance set at P < 0.05. Results: In the second trimester, there were no statistically significant differences between CRL and individual parameters: BPD, HC, FL, AC, TCD, and CPL ( P > 0.05). However, combined TCD and CPL differ significantly from CRL. In the third trimester, significant differences were found between BPD, HC, and AC with CRL ( P < 0.05), while FL, TCD, and CPL remained consistent with CRL ( P > 0.05). Conclusion: TCD and CPL are reliable alternatives to conventional biometric parameters for GA estimation in the second and third trimesters. However, CPL exhibited some variation in late pregnancy and should be combined with the TCD for better accuracy.

Institutions

Publication Details

Journal
Journal of Clinical Sciences
Published
2025-10-01
DOI
https://doi.org/10.4103/jcls.jcls_94_25
Primary Topic
Pregnancy and preeclampsia studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Gestational age estimation using fetal transcerebellar diameter and choroid plexus length compared with conventional biometric parameters in healthy Nigerian women: A longitudinal study

Journal of Clinical Sciences
Pregnancy and preeclampsia studies
article

Gestational age estimation using fetal transcerebellar diameter and choroid plexus length compared with conventional biometric parameters in healthy Nigerian women: A longitudinal study

article en

Abstract

ABSTRACT Background: The decline in the accuracy of biparietal diameter (BPD), head circumference (HC), femur length (FL), and abdominal circumference (AC) as gestation advances has complicated the distinction between pre- and postterm pregnancies. This study evaluated the correlation between the gestational age (GA) obtained from transcerebellar diameter (TCD) and choroid plexus length (CPL) with the GA obtained using crown-rump length (CRL) and compared the GA obtained from TCD and CPL with the average GA from the conventional biometric parameters. Methods: This longitudinal prospective study was conducted from December 2023 to May 2025 on 204 pregnant women between 14 and 40 weeks of gestation in a private hospital in Nigeria. A Mindray DC-7 ultrasound system, with a 3.5 MHz curvilinear probe, was used. TCD and CPL were measured using the suboccipitobregmatic and transventricular planes, respectively. Data were analyzed using paired sample t- tests, with statistical significance set at P < 0.05. Results: In the second trimester, there were no statistically significant differences between CRL and individual parameters: BPD, HC, FL, AC, TCD, and CPL ( P > 0.05). However, combined TCD and CPL differ significantly from CRL. In the third trimester, significant differences were found between BPD, HC, and AC with CRL ( P < 0.05), while FL, TCD, and CPL remained consistent with CRL ( P > 0.05). Conclusion: TCD and CPL are reliable alternatives to conventional biometric parameters for GA estimation in the second and third trimesters. However, CPL exhibited some variation in late pregnancy and should be combined with the TCD for better accuracy.

Journal of Clinical SciencesVol. 22(4)
University of Nigeria (NG), Enugu State University of Science and Technology (NG), Delta State Polytechnic Ogwashi-Uku (NG)
Good health and well-being
Openalex Percentile: Top 27%
Pregnancy and preeclampsia studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Gestational age estimation using fetal transcerebellar diameter and choroid plexus length compared with conventional biometric parameters in healthy Nigerian women: A longitudinal study · Journal of Clinical Sciences (2025) | TGRS Research Map | TGRS