Microplate assay for the quantification of catalase activity in biological samples

Catalase is a key antioxidant enzyme that protects cells from oxidative stress by decomposing hydrogen peroxide (H<sub>2</sub>O<sub>2</sub>). Traditional methods for quantifying catalase activity, such as the Aebi UV method and the dichromate assay, are limited by low sensitivity, interference from biological molecules and require large sample and reagent volumes. Here, we present an optimized, microplate assay based on the oxidation of cobalt(II) to cobalt(III) by H<sub>2</sub>O<sub>2</sub>, followed by complexation with ethylenediamine-tetraacetic acid (EDTA) to form a highly colored Co(III)-EDTA complex measurable at 570 nm. This method demonstrates superior sensitivity and dynamic range (10-0.039 U/mL) compared to previous colorimetric assays, while minimizing reaction volume and avoiding interference from common biological substances. The assay has been validated using standard bovine liver catalase, liver homogenates, serum and cell lysates, showing strong linearity and specificity. This approach offers a rapid, cost-effective, and robust alternative for catalase activity measurement in biomedical research.

Institutions

Publication Details

Journal
Methods
Published
2025-12-19
DOI
https://doi.org/10.1016/j.ymeth.2025.12.009
Primary Topic
Advanced Nanomaterials in Catalysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Microplate assay for the quantification of catalase activity in biological samples

Methods
Advanced Nanomaterials in Catalysis
article

Microplate assay for the quantification of catalase activity in biological samples

article en

Abstract

Catalase is a key antioxidant enzyme that protects cells from oxidative stress by decomposing hydrogen peroxide (H<sub>2</sub>O<sub>2</sub>). Traditional methods for quantifying catalase activity, such as the Aebi UV method and the dichromate assay, are limited by low sensitivity, interference from biological molecules and require large sample and reagent volumes. Here, we present an optimized, microplate assay based on the oxidation of cobalt(II) to cobalt(III) by H<sub>2</sub>O<sub>2</sub>, followed by complexation with ethylenediamine-tetraacetic acid (EDTA) to form a highly colored Co(III)-EDTA complex measurable at 570 nm. This method demonstrates superior sensitivity and dynamic range (10-0.039 U/mL) compared to previous colorimetric assays, while minimizing reaction volume and avoiding interference from common biological substances. The assay has been validated using standard bovine liver catalase, liver homogenates, serum and cell lysates, showing strong linearity and specificity. This approach offers a rapid, cost-effective, and robust alternative for catalase activity measurement in biomedical research.

MethodsVol. 246
University of the Basque Country (ES)
Clean water and sanitation
Openalex Percentile: Top 49%
Advanced Nanomaterials in Catalysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.