Investigation of conduction processes of <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" altimg="si4.svg" display="inline" id="d1e159"> <mml:mi>γ</mml:mi> </mml:math> -irradiated EPR insulation by conduction current and extended voltage resp

The γ -irradiation initiates several degradation mechanisms in insulating polymers, including cross-linking, chain scission, and oxidation, thereby degrading both the mechanical and electrical properties of the materials. Traditionally, the elongation properties are used to qualify the functionality of polymers in radiation environments; however, there is a growing need for non-destructive material testing. One of the substantial advantages of testing electrical properties is that they can be non-destructively measured. Therefore, the conductive properties of γ -irradiated EPR insulation were investigated in this study. The subject of the research, EPR-insulated cable samples, was investigated using current and extended voltage response (EVR) measurements. The samples were irradiated at a dose rate of 0.8 kGy/h. The total absorbed dose was 1.2 MGy. The results showed that the conductive current and the slope of decay voltage increased steadily with absorbed dose. The activation energies of conductivity increased from the initial 0.8 eV to 2 eV after the total dose. From the trap distribution data, the de-trapping rates were calculated for shallow and deep traps. The de-trapping rate showed a strong correlation with conductivity; however, the de-trapping rate was greater for shallow traps, indicating the dominant role of shallow traps in conduction. • γ -irradiated EPR insulated NPP cable samples were investigated. • The samples were tested using conductive current and extended voltage response measurements. • The activation energy of conduction was increased with absorbed dose. • The calculated de-trapping rate from shallow traps showed a strong correlation with conductive currents.

Institutions

Publication Details

Journal
Journal of Electrostatics
Published
2025-12-18
DOI
https://doi.org/10.1016/j.elstat.2025.104228
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation of conduction processes of <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" altimg="si4.svg" display="inline" id="d1e159"> <mml:mi>γ</mml:mi> </mml:math> -irradiated EPR insulation by conduction current and extended voltage resp

Journal of Electrostatics
High voltage insulation and dielectric phenomena
article

Investigation of conduction processes of <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" altimg="si4.svg" display="inline" id="d1e159"> <mml:mi>γ</mml:mi> </mml:math> -irradiated EPR insulation by conduction current and extended voltage resp

article en

Abstract

The γ -irradiation initiates several degradation mechanisms in insulating polymers, including cross-linking, chain scission, and oxidation, thereby degrading both the mechanical and electrical properties of the materials. Traditionally, the elongation properties are used to qualify the functionality of polymers in radiation environments; however, there is a growing need for non-destructive material testing. One of the substantial advantages of testing electrical properties is that they can be non-destructively measured. Therefore, the conductive properties of γ -irradiated EPR insulation were investigated in this study. The subject of the research, EPR-insulated cable samples, was investigated using current and extended voltage response (EVR) measurements. The samples were irradiated at a dose rate of 0.8 kGy/h. The total absorbed dose was 1.2 MGy. The results showed that the conductive current and the slope of decay voltage increased steadily with absorbed dose. The activation energies of conductivity increased from the initial 0.8 eV to 2 eV after the total dose. From the trap distribution data, the de-trapping rates were calculated for shallow and deep traps. The de-trapping rate showed a strong correlation with conductivity; however, the de-trapping rate was greater for shallow traps, indicating the dominant role of shallow traps in conduction. • γ -irradiated EPR insulated NPP cable samples were investigated. • The samples were tested using conductive current and extended voltage response measurements. • The activation energy of conduction was increased with absorbed dose. • The calculated de-trapping rate from shallow traps showed a strong correlation with conductive currents.

Journal of ElectrostaticsVol. 139
Budapest University of Technology and Economics (HU), University of Bologna (IT)
Openalex Percentile: Top 49%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Investigation of conduction processes of <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" altimg="si4.svg" display="inline" id="d1e159"> <mml:mi>γ</mml:mi> </mml:math> -irradiated EPR insulation by conduction current and extended voltage resp · Journal of Electrostatics (2025) | TGRS Research Map | TGRS