Short-Term Outcomes of Two Self-Expanding Transcatheter Valves in Sievers Type 1 Bicuspid Aortic Valve Stenosis: The “Proof-of-Concept” CLASS Effect Study

Background: Self-expanding transcatheter heart valves (SEVs) are often used to treat Sievers type 1 bicuspid aortic valve (BAV) stenosis. It remains unclear, however, if different SEVs yield similar outcomes in BAV stenosis, a class effect, or if the unique design features of different SEVs produce disparate clinical results. Objectives: This is a “proof-of-concept” study that compares procedural and clinical outcomes of Acurate neo2 and Evolut Pro/Pro+/Fx platforms in Sievers type 1 BAV stenosis. Methods: The CLASS effect is a retrospective, multicenter registry that enrolls patients with raphe-type 1 BAV stenosis undergoing TAVI at 29 international centers, who received Acurate neo2 and Evolut Pro/Pro+/Fx devices. An inverse probability of treatment weighting (IPTW) analysis was performed to adjust for baseline imbalances. Primary endpoints included VARC-3 technical success, 30-day device success, and early safety according to VARC-3. Results: Among 389 eligible patients, 155 and 234 patients were treated with Acurate neo2 and Evolut platforms, respectively. A higher rate of technical success was observed in the Evolut group (Acurate neo2 vs. Evolut: 93.4% vs. 97.1%, OR 0.41, 95% CI 0.19–0.83, and p = 0.017). At 30 days, device success was comparable (90.1% vs. 89.4%, OR 1.09, 95% CI 0.68–1.75, and p = 0.733), whereas Acurate neo2 was associated with a higher rate of early safety (84.1% vs. 70.4%, OR 2.22, 95% CI 1.56–3.17, and p < 0.001), which was mainly driven by a lower risk of new permanent pacemaker implantation (PPI) (6.3% vs. 19.5%, OR 0.28, 95% CI 0.16–0.46, and p < 0.001). Conclusions: Acurate neo2 and Evolut Pro/Pro+/Fx platforms provide similarly effective procedural and short-term outcomes in Sievers type 1 BAV stenosis. However, Evolut was associated with a higher technical success, while Acurate neo2 demonstrated a lower incidence of new PPI.

Institutions

Publication Details

Journal
Journal of Vascular Diseases
Published
2025-12-18
DOI
https://doi.org/10.3390/jvd4040052
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Short-Term Outcomes of Two Self-Expanding Transcatheter Valves in Sievers Type 1 Bicuspid Aortic Valve Stenosis: The “Proof-of-Concept” CLASS Effect Study

Journal of Vascular Diseases
Cardiac Valve Diseases and Treatments
article

Short-Term Outcomes of Two Self-Expanding Transcatheter Valves in Sievers Type 1 Bicuspid Aortic Valve Stenosis: The “Proof-of-Concept” CLASS Effect Study

article en

Abstract

Background: Self-expanding transcatheter heart valves (SEVs) are often used to treat Sievers type 1 bicuspid aortic valve (BAV) stenosis. It remains unclear, however, if different SEVs yield similar outcomes in BAV stenosis, a class effect, or if the unique design features of different SEVs produce disparate clinical results. Objectives: This is a “proof-of-concept” study that compares procedural and clinical outcomes of Acurate neo2 and Evolut Pro/Pro+/Fx platforms in Sievers type 1 BAV stenosis. Methods: The CLASS effect is a retrospective, multicenter registry that enrolls patients with raphe-type 1 BAV stenosis undergoing TAVI at 29 international centers, who received Acurate neo2 and Evolut Pro/Pro+/Fx devices. An inverse probability of treatment weighting (IPTW) analysis was performed to adjust for baseline imbalances. Primary endpoints included VARC-3 technical success, 30-day device success, and early safety according to VARC-3. Results: Among 389 eligible patients, 155 and 234 patients were treated with Acurate neo2 and Evolut platforms, respectively. A higher rate of technical success was observed in the Evolut group (Acurate neo2 vs. Evolut: 93.4% vs. 97.1%, OR 0.41, 95% CI 0.19–0.83, and p = 0.017). At 30 days, device success was comparable (90.1% vs. 89.4%, OR 1.09, 95% CI 0.68–1.75, and p = 0.733), whereas Acurate neo2 was associated with a higher rate of early safety (84.1% vs. 70.4%, OR 2.22, 95% CI 1.56–3.17, and p < 0.001), which was mainly driven by a lower risk of new permanent pacemaker implantation (PPI) (6.3% vs. 19.5%, OR 0.28, 95% CI 0.16–0.46, and p < 0.001). Conclusions: Acurate neo2 and Evolut Pro/Pro+/Fx platforms provide similarly effective procedural and short-term outcomes in Sievers type 1 BAV stenosis. However, Evolut was associated with a higher technical success, while Acurate neo2 demonstrated a lower incidence of new PPI.

Journal of Vascular DiseasesVol. 4(4)
Cedars-Sinai Medical Center (US), Karolinska University Hospital (SE), Montefiore Medical Center (US), University of Padua (IT), Vita-Salute San Raffaele University (IT), University of Milan (IT), Justus-Liebig-Universität Gießen (DE), Sichuan University (CN), Università degli Studi di Enna Kore (IT), Leeds Teaching Hospitals NHS Trust (GB), Wolfson Medical Center (IL), Copenhagen University Hospital (DK), University Hospital Galway (IE), Rigshospitalet (DK), Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico (IT), University of Catania (IT), Ospedale Maggiore (IT), Centro Cardiologico Monzino (IT), West China Hospital of Sichuan University (CN), Azienda Socio Sanitaria Territoriale Grande Ospedale Metropolitano Niguarda (IT), IRCCS Policlinico San Donato (IT), Istituto Clinico Sant'Ambrogio (IT), Azienda Socio Sanitaria Territoriale degli Spedali Civili di Brescia (IT), Federico II University Hospital (IT), Azienda USL di Bologna (IT), Policlinico Universitario di Catania (IT), Kerckhoff Klinik (DE), Clinique Pasteur (FR), Cedars-Sinai Smidt Heart Institute (US), Ca' Foncello Hospital (IT), St.-Johannes-Hospital Dortmund (DE), Fondazione Poliambulanza Istituto Ospedaliero (IT), University of the Sacred Heart (JP), Carlo Forlanini Hospital (IT), Istituti di Ricovero e Cura a Carattere Scientifico (IT), Hospital Universitari Germans Trias i Pujol (ES), Hospital Clínico Universitario de Valladolid (ES), IRCCS Humanitas Research Hospital (IT), Azienda Ospedaliera Universitaria Pisana (IT), Istituto di Ricovero e Cura a Carattere Scientifico San Raffaele (IT), University of Milano-Bicocca (IT), University of Naples Federico II (IT), University of Brescia (IT)
Openalex Percentile: Top 32%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.