A phase-demodulation based time drift compensation for the reduction of the 50/60 Hz power line interference in biopotentials

The 50/60 Hz power line interference (PLI) usually causes significant degradation to biopotentials and other low amplitude electrical signals. In this manuscript a numerical procedure for the reduction of the PLI interference, based on time drift compensation, is presented. The time drift compensation provides the cancellation of the PLI frequency drift and the minimization of the spectral width of the PLI harmonics, which allows an efficient reduction of this interference with minimum distortion of the signal of interest. The procedure (A) selects one PLI harmonic appropriate for the estimation of the time drift associated to the frequency drift and estimates the time drift by phase demodulation of the selected harmonic; (B) transforms the signal to a time scale where the time drift (and therefore also the frequency drift) is canceled; (C) efficiently reduces the PLI components with minimal distortion of the signal; and finally (D) transforms the signal back to the original time scale. The procedure provides biopotentials substantially free of PLI. Examples of MatLab/Octave implementations of the procedure are provided, as well as examples of applications in the context of electrocardiography and auditory evoked potentials. The proposed method, applied to signals acquired in real scenarios, provides a substantial improvement with respect to conventional notch comb filtering without time drift compensation. • Reduction of power line interference (PLI) is difficult due to the frequency drift. • The frequency drift is associated to a time drift. • The time drift can be estimated and compensated. • After the time drift compensation, the frequency drift is canceled. • The frequency drift cancellation makes the PLI reduction accurate and effective.

Institutions

Publication Details

Journal
Biomedical Signal Processing and Control
Published
2025-12-17
DOI
https://doi.org/10.1016/j.bspc.2025.109423
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A phase-demodulation based time drift compensation for the reduction of the 50/60 Hz power line interference in biopotentials

Biomedical Signal Processing and Control
ECG Monitoring and Analysis
article

A phase-demodulation based time drift compensation for the reduction of the 50/60 Hz power line interference in biopotentials

article en

Abstract

The 50/60 Hz power line interference (PLI) usually causes significant degradation to biopotentials and other low amplitude electrical signals. In this manuscript a numerical procedure for the reduction of the PLI interference, based on time drift compensation, is presented. The time drift compensation provides the cancellation of the PLI frequency drift and the minimization of the spectral width of the PLI harmonics, which allows an efficient reduction of this interference with minimum distortion of the signal of interest. The procedure (A) selects one PLI harmonic appropriate for the estimation of the time drift associated to the frequency drift and estimates the time drift by phase demodulation of the selected harmonic; (B) transforms the signal to a time scale where the time drift (and therefore also the frequency drift) is canceled; (C) efficiently reduces the PLI components with minimal distortion of the signal; and finally (D) transforms the signal back to the original time scale. The procedure provides biopotentials substantially free of PLI. Examples of MatLab/Octave implementations of the procedure are provided, as well as examples of applications in the context of electrocardiography and auditory evoked potentials. The proposed method, applied to signals acquired in real scenarios, provides a substantial improvement with respect to conventional notch comb filtering without time drift compensation. • Reduction of power line interference (PLI) is difficult due to the frequency drift. • The frequency drift is associated to a time drift. • The time drift can be estimated and compensated. • After the time drift compensation, the frequency drift is canceled. • The frequency drift cancellation makes the PLI reduction accurate and effective.

Biomedical Signal Processing and ControlVol. 115
Universidad de Granada (ES)
Ministerio de Ciencia e Innovación, Junta de Andalucía
Openalex Percentile: Top 32%
ECG Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.