The utility of locking plate fixation combined with intraosseous wiring for an intra-articular depressed fracture of the middle phalangeal base: A case report

Comminuted depressed fractures at the base of the middle phalanx are often difficult to treat with a single fixation method, as achieving both anatomic reduction and stable fixation can be challenging. While soft stainless steel wire fixation and locking plate fixation have each been used individually as definitive treatments, no reports to date have described a combined approach. We present the case of a 74-year-old man with comminuted depressed fractures at the base of the middle and ring finger middle phalanges, successfully treated using a locking plate in combination with soft stainless steel wire. The addition of the wire allowed for temporary stabilization of fracture fragments, prevented displacement during screw insertion, and improved overall construct stability. This technique also enabled early postoperative rehabilitation to reduce the risk of adhesion. The combined use of soft stainless steel wire and locking plate fixation may represent a useful strategy for managing complex fractures of the middle phalanx base.

Institutions

Publication Details

Journal
Trauma Case Reports
Published
2025-12-17
DOI
https://doi.org/10.1016/j.tcr.2025.101293
Primary Topic
Orthopedic Surgery and Rehabilitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The utility of locking plate fixation combined with intraosseous wiring for an intra-articular depressed fracture of the middle phalangeal base: A case report

Trauma Case Reports
Orthopedic Surgery and Rehabilitation
article

The utility of locking plate fixation combined with intraosseous wiring for an intra-articular depressed fracture of the middle phalangeal base: A case report

article en

Abstract

Comminuted depressed fractures at the base of the middle phalanx are often difficult to treat with a single fixation method, as achieving both anatomic reduction and stable fixation can be challenging. While soft stainless steel wire fixation and locking plate fixation have each been used individually as definitive treatments, no reports to date have described a combined approach. We present the case of a 74-year-old man with comminuted depressed fractures at the base of the middle and ring finger middle phalanges, successfully treated using a locking plate in combination with soft stainless steel wire. The addition of the wire allowed for temporary stabilization of fracture fragments, prevented displacement during screw insertion, and improved overall construct stability. This technique also enabled early postoperative rehabilitation to reduce the risk of adhesion. The combined use of soft stainless steel wire and locking plate fixation may represent a useful strategy for managing complex fractures of the middle phalanx base.

Trauma Case ReportsVol. 61
Hokkaido University (JP), Obihiro Kosei General Hospital (JP), Sendai City Hospital (JP)
Sustainable cities and communities
Openalex Percentile: Top 28%
Orthopedic Surgery and Rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The utility of locking plate fixation combined with intraosseous wiring for an intra-articular depressed fracture of the middle phalangeal base: A case report · Trauma Case Reports (2025) | TGRS Research Map | TGRS