Precision silver carp allergy profiling and rapid IgE epitope mapping by a microfluidic chip-MALDI-TOF MS system and prediction models

Food allergies are increasing at an alarming rate, and it has become necessary to identify patient-specific allergens for personalized allergy immunotherapy treatments. Herein, a precision fish allergy test was established for patient-specific allergen identification and IgE epitope mapping in silver carp by employing an integrated microfluidic chip-MALDI-TOF MS system. Tosyl-activated magnetic beads (MGBs) were functionalized with mouse monoclonal anti-human immunoglobulin E (IgE) antibodies and patient serum to form IgE-MGBs. For patient-specific allergen identification, silver carp (<i>Hypophthalmichthys molitrix</i>) muscle protein extracts were mixed with IgE-MGBs and injected into a microfluidic channel to capture allergenic proteins. Captured allergens were eluted, trypsin-digested, and characterized by MALDI-TOF MS and peptide mass fingerprinting. To map IgE epitopes, tryptic peptides from silver carp proteins were similarly captured by IgE-MGBs and characterized by MALDI-TOF MS and peptide mass fingerprinting. Ten potential allergens were identified from silver carp, nine of which are novel to this fish based on the use of fish allergic serum samples. The allergenicity of identified proteins was predicted using AlgPred and ALLERDET tools, while IgE epitopes were predicted by Bepipred Linear Epitope Prediction 2.0 and experimentally validated <i>via</i> the microfluidic chip-MALDI-TOF MS system. ELISA confirmed the protocol, showing a parvalbumin content of 458.2 µg g<sup>-1</sup> in fish muscle. Comparison of fish allergy diagnosis methods further demonstrates the potential of the microfluidic chip-MALDI-TOF MS system to personalize fish allergy detection and aid in identifying patient-specific allergens and IgE epitopes for immunotherapy development.

Institutions

Publication Details

Journal
The Analyst
Published
2025-12-17
DOI
https://doi.org/10.1039/d5an01161b
Primary Topic
Food Allergy and Anaphylaxis Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Precision silver carp allergy profiling and rapid IgE epitope mapping by a microfluidic chip-MALDI-TOF MS system and prediction models

The Analyst
Food Allergy and Anaphylaxis Research
article

Precision silver carp allergy profiling and rapid IgE epitope mapping by a microfluidic chip-MALDI-TOF MS system and prediction models

article en

Abstract

Food allergies are increasing at an alarming rate, and it has become necessary to identify patient-specific allergens for personalized allergy immunotherapy treatments. Herein, a precision fish allergy test was established for patient-specific allergen identification and IgE epitope mapping in silver carp by employing an integrated microfluidic chip-MALDI-TOF MS system. Tosyl-activated magnetic beads (MGBs) were functionalized with mouse monoclonal anti-human immunoglobulin E (IgE) antibodies and patient serum to form IgE-MGBs. For patient-specific allergen identification, silver carp (<i>Hypophthalmichthys molitrix</i>) muscle protein extracts were mixed with IgE-MGBs and injected into a microfluidic channel to capture allergenic proteins. Captured allergens were eluted, trypsin-digested, and characterized by MALDI-TOF MS and peptide mass fingerprinting. To map IgE epitopes, tryptic peptides from silver carp proteins were similarly captured by IgE-MGBs and characterized by MALDI-TOF MS and peptide mass fingerprinting. Ten potential allergens were identified from silver carp, nine of which are novel to this fish based on the use of fish allergic serum samples. The allergenicity of identified proteins was predicted using AlgPred and ALLERDET tools, while IgE epitopes were predicted by Bepipred Linear Epitope Prediction 2.0 and experimentally validated <i>via</i> the microfluidic chip-MALDI-TOF MS system. ELISA confirmed the protocol, showing a parvalbumin content of 458.2 µg g<sup>-1</sup> in fish muscle. Comparison of fish allergy diagnosis methods further demonstrates the potential of the microfluidic chip-MALDI-TOF MS system to personalize fish allergy detection and aid in identifying patient-specific allergens and IgE epitopes for immunotherapy development.

The AnalystVol. 151(3)
Second Military Medical University (CN), Changhai Hospital (CN), Shanghai Ocean University (CN)
Zero hunger
Openalex Percentile: Top 30%
Food Allergy and Anaphylaxis Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.