Integrated Boost vs. Sequential Scheme in Volumetric Modulated Arc Therapy (VMAT) for Trimodal Bladder Cancer Therapy: A Comparative Study

Background Trimodal therapy (TMT), combining transurethral resection of the bladder tumor, radiotherapy, and concurrent chemotherapy, is an established bladder-preserving approach for muscle-invasive bladder cancer (MIBC). Advances in radiotherapy, such as volumetric modulated arc therapy (VMAT), have enabled the use of different dose delivery schemes, namely simultaneous integrated boost (SIB) and sequential boost (SEQ) techniques. This study aimed to compare dosimetric outcomes, organ-at-risk sparing, and treatment tolerance between these two VMAT schemes. Methods Fourteen patients with MIBC treated with TMT between December 2016 and December 2021 were retrospectively analyzed. Seven patients received SIB-VMAT, and seven received SEQ-VMAT. Treatment plans were generated using Eclipse<sup>®</sup> software (Varian Medical Systems, Palo Alto, CA, United States), and dose-volume parameters were evaluated for the rectum, small bowel, and femoral heads. Tumor response and toxicities were assessed according to CTCAE v6.0 criteria. Statistical analyses were performed using IBM SPSS Statistics for Windows, Version 25.0 (Released 2017; IBM Corp., Armonk, NY, USA). Results Target coverage and conformity were comparable between SIB and SEQ plans (V98%: 95.7% vs. 96.8%; V2%: 102.2% vs. 101.9%). Rectal and femoral head doses were similar across both schemes, whereas the small bowel received higher V15Gy and V45Gy in the SIB group (863.6 mL and 130.6 mL vs. 517.3 mL and 71.6 mL, respectively). Acute toxicities were predominantly urinary (Grade 1-2 cystitis) and occurred in 21.4% of patients. The complete response rate was slightly higher in the SIB group (18%) compared with the SEQ group (17%), although the difference was not statistically significant. Conclusions Both SIB and SEQ-VMAT schemes provide effective and well-tolerated treatment options for bladder preservation in MIBC. SIB offers a shorter overall treatment duration and marginally improved target conformity, while SEQ may better spare the small bowel at lower dose levels. The choice between these approaches can be individualized according to patient anatomy and institutional expertise.

Institutions

Publication Details

Journal
Cureus
Published
2025-12-17
DOI
https://doi.org/10.7759/cureus.99438
Primary Topic
Bladder and Urothelial Cancer Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Integrated Boost vs. Sequential Scheme in Volumetric Modulated Arc Therapy (VMAT) for Trimodal Bladder Cancer Therapy: A Comparative Study

Cureus
Bladder and Urothelial Cancer Treatments
article

Integrated Boost vs. Sequential Scheme in Volumetric Modulated Arc Therapy (VMAT) for Trimodal Bladder Cancer Therapy: A Comparative Study

article en

Abstract

Background Trimodal therapy (TMT), combining transurethral resection of the bladder tumor, radiotherapy, and concurrent chemotherapy, is an established bladder-preserving approach for muscle-invasive bladder cancer (MIBC). Advances in radiotherapy, such as volumetric modulated arc therapy (VMAT), have enabled the use of different dose delivery schemes, namely simultaneous integrated boost (SIB) and sequential boost (SEQ) techniques. This study aimed to compare dosimetric outcomes, organ-at-risk sparing, and treatment tolerance between these two VMAT schemes. Methods Fourteen patients with MIBC treated with TMT between December 2016 and December 2021 were retrospectively analyzed. Seven patients received SIB-VMAT, and seven received SEQ-VMAT. Treatment plans were generated using Eclipse<sup>®</sup> software (Varian Medical Systems, Palo Alto, CA, United States), and dose-volume parameters were evaluated for the rectum, small bowel, and femoral heads. Tumor response and toxicities were assessed according to CTCAE v6.0 criteria. Statistical analyses were performed using IBM SPSS Statistics for Windows, Version 25.0 (Released 2017; IBM Corp., Armonk, NY, USA). Results Target coverage and conformity were comparable between SIB and SEQ plans (V98%: 95.7% vs. 96.8%; V2%: 102.2% vs. 101.9%). Rectal and femoral head doses were similar across both schemes, whereas the small bowel received higher V15Gy and V45Gy in the SIB group (863.6 mL and 130.6 mL vs. 517.3 mL and 71.6 mL, respectively). Acute toxicities were predominantly urinary (Grade 1-2 cystitis) and occurred in 21.4% of patients. The complete response rate was slightly higher in the SIB group (18%) compared with the SEQ group (17%), although the difference was not statistically significant. Conclusions Both SIB and SEQ-VMAT schemes provide effective and well-tolerated treatment options for bladder preservation in MIBC. SIB offers a shorter overall treatment duration and marginally improved target conformity, while SEQ may better spare the small bowel at lower dose levels. The choice between these approaches can be individualized according to patient anatomy and institutional expertise.

CureusVol. 17(12)
Université Mohammed VI des Sciences et de la Santé (MA), Hôpital Universitaire International Cheikh Khalifa (MA)
Good health and well-being
Openalex Percentile: Top 28%
Bladder and Urothelial Cancer Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.