Linear optical-feedback cavity ring-down spectroscopy using an interband cascade laser at 3- <i>µ</i> m wavelength

We report on a linear optical-feedback cavity ring-down spectrometer (LOF-CRDS) operating under ultra-high vacuum (UHV) conditions, designed for high-sensitivity detection of light hydrocarbons. The system employs an interband cascade laser (ICL) operating at 3 <i>µ</i>m, in coincidence with the strong absorption features of the asymmetric C-H stretching vibrational mode. Taking advantage of the passive optical feedback from the high-finesse linear cavity, the ICL emission linewidth is drastically narrowed, thus facilitating light coupling into the cavity. An empty-cavity ring-down time of about 18 <i>µ</i>s was measured, which translates into a cavity finesse of ∼37000 and a cavity-mode width of ∼9 kHz. As a result of an Allan-Werle analysis, performed at a fixed ICL frequency, we determined a minimum detectable absorption coefficient of ∼2.5×10<sup>-10</sup> cm<sup>-1</sup> for an integration time of approximately 100 s. The spectrometer was tested on the R(25) component of the acetylene <i>ν</i><sub>3</sub> vibrational band at 3352.2874 cm<sup>-1</sup>. In this regard, we report on spectroscopic measurements of the C<sub>2</sub>H<sub>2</sub> partial pressure in the UHV chamber. For the selected line, the sensitivity leads to a limit of detection of 2.1×10<sup>-8</sup> mbar.

Institutions

Publication Details

Journal
Optics Express
Published
2025-12-17
DOI
https://doi.org/10.1364/oe.581115
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Linear optical-feedback cavity ring-down spectroscopy using an interband cascade laser at 3- µ m wavelength

Optics Express
Spectroscopy and Laser Applications
article

Linear optical-feedback cavity ring-down spectroscopy using an interband cascade laser at 3- µ m wavelength

article en

Abstract

We report on a linear optical-feedback cavity ring-down spectrometer (LOF-CRDS) operating under ultra-high vacuum (UHV) conditions, designed for high-sensitivity detection of light hydrocarbons. The system employs an interband cascade laser (ICL) operating at 3 <i>µ</i>m, in coincidence with the strong absorption features of the asymmetric C-H stretching vibrational mode. Taking advantage of the passive optical feedback from the high-finesse linear cavity, the ICL emission linewidth is drastically narrowed, thus facilitating light coupling into the cavity. An empty-cavity ring-down time of about 18 <i>µ</i>s was measured, which translates into a cavity finesse of ∼37000 and a cavity-mode width of ∼9 kHz. As a result of an Allan-Werle analysis, performed at a fixed ICL frequency, we determined a minimum detectable absorption coefficient of ∼2.5×10<sup>-10</sup> cm<sup>-1</sup> for an integration time of approximately 100 s. The spectrometer was tested on the R(25) component of the acetylene <i>ν</i><sub>3</sub> vibrational band at 3352.2874 cm<sup>-1</sup>. In this regard, we report on spectroscopic measurements of the C<sub>2</sub>H<sub>2</sub> partial pressure in the UHV chamber. For the selected line, the sensitivity leads to a limit of detection of 2.1×10<sup>-8</sup> mbar.

Optics ExpressVol. 34(5)
Istituto Nazionale di Fisica Nucleare (IT), University of Perugia (IT), Azienda Ospedaliera Universitaria Università degli Studi della Campania Luigi Vanvitelli (IT)
Affordable and clean energy
Openalex Percentile: Top 41%
Spectroscopy and Laser Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.