Harmonic Analysis of Shipboard Power Systems Considering VFD Loads

In recent shipboard power systems, variable-frequency drive (VFD) loads are increasingly used not only for propulsion but also for operating various auxiliary devices such as fans, pumps, and compressors. Given that most VFDs employ diode rectifiers, the inclusion of multiple VFD loads leads to significant degradation of voltage and current waveforms in the power system. According to classification society regulations, the voltage total harmonic distortion (THD) must generally remain below 8%, with individual harmonic components not exceeding 5%. However, these limits are often exceeded as the proportion of VFD loads increases. This paper presents a detailed harmonic analysis of shipboard power system under varying VFD load ratios, filter installation conditions, and system inductance levels. In particular this study identifies the critical VFD load ratio beyond which the harmonic distortion exceeds classification limits and proposes the appropriate sizing of passive filters to mitigate this issue. Furthermore, it investigates the nonlinear relationship between system inductance and VFD load ratio, offering predictive insights into THD behavior under different system conditions.

Publication Details

Journal
The Transactions of the Korean Institute of Power Electronics
Published
2025-12-17
DOI
https://doi.org/10.6113/tkpe.2025.30.6.506
Primary Topic
Power Quality and Harmonics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Harmonic Analysis of Shipboard Power Systems Considering VFD Loads

The Transactions of the Korean Institute of Power Electronics
Power Quality and Harmonics
article

Harmonic Analysis of Shipboard Power Systems Considering VFD Loads

article en

Abstract

In recent shipboard power systems, variable-frequency drive (VFD) loads are increasingly used not only for propulsion but also for operating various auxiliary devices such as fans, pumps, and compressors. Given that most VFDs employ diode rectifiers, the inclusion of multiple VFD loads leads to significant degradation of voltage and current waveforms in the power system. According to classification society regulations, the voltage total harmonic distortion (THD) must generally remain below 8%, with individual harmonic components not exceeding 5%. However, these limits are often exceeded as the proportion of VFD loads increases. This paper presents a detailed harmonic analysis of shipboard power system under varying VFD load ratios, filter installation conditions, and system inductance levels. In particular this study identifies the critical VFD load ratio beyond which the harmonic distortion exceeds classification limits and proposes the appropriate sizing of passive filters to mitigate this issue. Furthermore, it investigates the nonlinear relationship between system inductance and VFD load ratio, offering predictive insights into THD behavior under different system conditions.

The Transactions of the Korean Institute of Power ElectronicsVol. 30(6)
Affordable and clean energy
Openalex Percentile: Top 44%
Power Quality and Harmonics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.